- As Posted On www.thisoldhouse.comThe architecture may be old at This Old House's new project in Austin, Texas, but the thinking is thoroughly modern. For the first time, the show is going totally "green"—using as many environmentally friendly building products and methods as possible—and creating a functional home for a contemporary blended family.
The subject of the renovation is a 1926 Craftsman bungalow that owners Michael Klug, 38, co-founder of a hologram company, and Michele Grieshaber, 41, a marketing executive, are turning from a two-bedroom, one-bathroom house into one with four bedrooms and two baths. Michele has owned the house for the past decade, but the couple married this past April and need more room to accommodate their new family, which includes Michael's two sons, Sam, 13, and David, 11. Add in the possibility of another child in the future, and it becomes clear that a house built for the lifestyle of a 1920s family won't cut it for this 21st-century clan.
That said, there are many things about the house's original design that the couple plans to preserve and honor. Built before the days of hulking McMansions with 24/7 air-conditioning, the compact house was built to use natural air flow, high rooflines, and deep overhanging eaves to keep the heat at bay. It was efficient and green, and Michael and Michele have no intention of turning it into a oversized, over-cooled monstrosity devoid of its original Arts and Crafts details. In fact, their second-floor addition will only bump up the roofline by 6 feet. "We don't want a big house; we're not going to gold-plate everything," says Michele. "We don't need fancy—we need functional."Along with the added bedrooms, the couple's other wish-list item is an updated kitchen that opens up onto an entertaining area. Walls will move or come down entirely to allow the couple to interact with friends and family while preparing food. "I love to cook, and I'm at the stove while I'm socializing," says Michael. They also plan to spend as much time outside in the mild weather, so they'll create a screened-in porch and make sure that the entertaining areas connect easily to the outdoors. "We like to live outside more than the average Texan," explains Michael. "We're fine not having the AC on."
That energy-saving mentality is one reason for their desire for a green renovation, but it may be the local way of life that truly influenced them. Austin, a young, tech-company town and one of the fastest growing cities in America, is at the forefront of the green movement. The Austin Green Building Program, one of the oldest in the country, will rate the project for its use of eco-friendly materials. Photovoltaic cells on the roof, rainwater collection for irrigation, spray-foam insulation, recycled-glass tile and countertops, and formaldehyde-free wood composites are just some of the resource-saving strategies and eco-friendly materials planned for the project.
Overseeing it all will be architect David Webber and veteran green builder Bill Moore. With a budget of $250,000, they'll be working hard to incorporate the right materials and still accomplish the changes the couple need. The project will take less than five months overall, but when it's finished, Michael and Michele will have an updated version of their classic house, which they loved so much they couldn't part with it. "We did look at other, renovated houses in the neighborhood," says Michele. "But I feel responsible for this house. Houses have souls, and I need to take care of this one."
Showing posts with label Energy Saving. Show all posts
Showing posts with label Energy Saving. Show all posts
6.16.2013
This Old (green) House
5.27.2013
TED Talks: Catherine Mohr presents green building and embodied energy
In this short, funny, data-packed talk at TED U, Catherine Mohr walks through all the geeky decisions she made when building a green new house -- looking at real energy numbers, not hype. What choices matter most? Not the ones you think.
http://www.ted.com/talks/catherine_mohr_builds_green.html
Catherine Mohr began her career as an engineer, working for many years with Paul MacCready at AeroVironment to develop alternative-energy vehicles and high-altitude aircraft. Her midcareer break: medical school, where she invented a brilliantly simple device, the LapCap, that makes laproscopic surgeries safer.
Mohr now oversees the development of next-generation surgical robots and robotic procedures, as the director of medical research at Intuitive Surgical Inc., where she's the clinical design leader for the DaVinci Surgical Robotic system. She also works at Stanford's School of Medicine, where she studies simulation-based teaching methods to teach clinical skills to budding doctors. And she's a senior scientific advisor to the GlobalSolver Foundation, an innovative funding and study group that looks at ways to match up scientists and money to help the world's oceans.
Now visit World Class Supply for materials that do a world of good!
http://www.ted.com/talks/catherine_mohr_builds_green.html
Catherine Mohr began her career as an engineer, working for many years with Paul MacCready at AeroVironment to develop alternative-energy vehicles and high-altitude aircraft. Her midcareer break: medical school, where she invented a brilliantly simple device, the LapCap, that makes laproscopic surgeries safer.
Mohr now oversees the development of next-generation surgical robots and robotic procedures, as the director of medical research at Intuitive Surgical Inc., where she's the clinical design leader for the DaVinci Surgical Robotic system. She also works at Stanford's School of Medicine, where she studies simulation-based teaching methods to teach clinical skills to budding doctors. And she's a senior scientific advisor to the GlobalSolver Foundation, an innovative funding and study group that looks at ways to match up scientists and money to help the world's oceans.
Now visit World Class Supply for materials that do a world of good!
5.17.2013
5 Ways You Can Lower Your Utility Bills This Summer
Excerpted
from : thegoodhuman.com
May
01st, 2013
1. Utilize Rain Barrels
Collecting
rainwater from your roof and using it to water your garden will slash
the amount of water consumption your household uses during
the hot summer months. During the growing season, homeowners can save
around 1,300 gallons of water, which adds up to a large amount on the
water bill. Just half an inch of water is often enough to fill a
50-gallon rain barrel. If you install a few of these barrels, you may
not need to turn the main tap on all year.Planting trees to the south and west of your house can lower energy consumption by around 5% in the summertime due to the shade it provided on the house. The bigger the trees the better, as they provide more shade for the house.
3. Use Solar Shades
If your home has lots
of south-facing windows, the solar energy entering your home could be
dramatically heating the property and costing you money to try and
keep it cool again. Solar shades are a low-cost, effective
way to reduce the amount of heat entering your home, and this will
dramatically lower your electricity bill as you will not have to use
fans or air conditioning nearly as much.
4. Keep it Clean
If you’re using
an air conditioning unit, it’s essential that you carry out a
monthly maintenance routine in order to keep the filters clean and
the system working efficiently. A blocked filter can cost you money
as the machine is not working as effectively as it could. Also,
keeping your house clean tidy, and clutter free will increase the
airflow around the property which also helps to lower the cost of
cooling.
5. Alter Your Diet
During the summer
months when you spend all day trying to keep the house cool, putting
the oven on for hours at a time to cook your dinner or bake a cake is
simply counter-productive. This can cause a huge temperature rise in
your home and will cost more money to keep the temperature low during
this time. Either cut down on your oven use and eat more salads and
cool foods, or shut the kitchen door so that you are only heating one
room.Each of these simple steps may only make a small difference to the cost of your utility bills over the summer. If you make a lot of new habits over the coming months, trying to reduce energy consumption in lots of different ways, you will notice the reduction in your bills.
Find money saving and eco-friendly building and cleaning solutions at World Class Supply !
5.16.2013
What Are Solar Roof Shingles?
April
01st, 2013
EarthTalk is written and edited by Roddy Scheer and Doug Moss and is a registered trademark of E The Environmental Magazine (www.emagazine.com).
Q: I’m getting my roof redone and have heard about solar roof shingles. Are they available—and are they practical for the Northeast?
Solar
shingles are photovoltaic
cells designed
to look like and integrate with conventional asphalt roof shingles.
First commercially available in 2005, solar shingles were much more
costly than traditional “bolt-on” photovoltaic panels, and thus
were used mainly by those wanting to go solar but maintain a
traditional roofline. But more recently solar shingles have become
price-competitive with bolt-on panels, and are getting much more
popular accordingly. Eco-conscious home and building owners might
find solar shingles especially attractive when they are re-shingling
anyway since the solar shingles also double as functional, protective
and weatherproof roof shingles in their own right.
The
biggest name in solar shingles is Dow’s Powerhouse line, which uses
cutting edge Copper Indium Gallium Selenide solar cells (aka
“thin-film” solar) to turn sunlight into electricity via a
supplied inverter box. The Powerhouse shingles generate 12
watts per square foot and
are “grid-tied,” meaning they’re designed for structures
already connected to the power grid and can send excess power back to
the grid. They are wireless, snap together and can be installed by
regular roofing contractors just like (or alongside) conventional
asphalt shingles (an electrician needs to set up the inverter box).
Dow
reports that a typical residential cluster of 350 solar singles on a
roof could slash one’s household electric bill by 40-60 percent.
Such an installation can cost a homeowner over $20,000, but federal,
state and local incentives can bring the cost to half that in some
areas. Powerhouse shingles are currently available (from
Dow-authorized contractors) in California, Colorado, Connecticut,
Louisiana, Maryland, Massachusetts, Michigan, New York, North
Carolina, Texas and Washington, D.C.
Another
leader in solar shingles is building products manufacturer
CertainTeed. The company’s Apollo line of grid-tied monocrystalline
solar shingles and roofing tiles offers efficiency similar to larger
“bolt-on” photovoltaic arrays at around the same price (and
incentives similar to those for Dow may also apply) but with less
bulk: Each Apollo tile is less than an inch thick and will integrate
with, replace, or lay on top of existing asphalt roof shingles or
tiles and generate 12 watts of power per square foot.
CertainTeed
says a typical installation will save homeowners 40-70
percent on their electric bills.
Their Apollo products are available across the U.S. but the company
recommends using one of their authorized roofing contractors to make
sure they are installed properly.
Now
is an especially good time to go solar—shingles or
otherwise—because costs have started to come down and the federal
government is still offering 30 percent tax credits with no cap on
the purchase of solar electricity equipment. Twenty-seven states and
several cities offer additional incentives that can get pricing on
solar gear and installations down even lower. For more information
check out the Database of State Incentives for Renewables and
Efficiency (DSIRE), a free online resource provided by the North
Carolina Solar Center and IREC with funding from the U.S. Department
of Energy.
Send questions to: earthtalk@emagazine.com.
Subscribe:www.emagazine.com/subscribe;
Free Trial Issue: www.emagazine.com/trial.
4.18.2013
Amory Lovins, 50 Year Energy Authority
Amory
B. Lovins, a 65-year-old American consultant, experimental physicist and 1993
MacArthur Fellow, has been active at the nexus of energy, resources,
environment, development, and security in more than 50 countries for 35 years,
including 14 years based in England. He is widely considered among the world’s
leading authorities on energy—especially its efficient use and sustainable
supply—and a fertile innovator in integrative design.
After
two years at Harvard, Mr. Lovins transferred to Oxford, and two years later
became a don at 21, receiving in consequence an Oxford MA by Special Resolution
(1971) and, later, 11 honorary doctorates of various U.S. and U.K.
universities. He has been Regents’ Lecturer at the U. of California both in
Energy and Resources and in Economics; Grauer Lecturer at UBC; Luce Visiting
Professor at Dartmouth; Distinguished Visiting Professor at the University of
Colorado; Oikos Visiting Professor of Business, U. of St. Gallen; an
engineering visiting professor at Peking U.; and 2007 MAP/Ming Professor at
Stanford’s School of Engineering.
During
1979–2002, Mr. Lovins worked as a team with Hunter Lovins (his wife 1979–99).
They shared a 1982 Mitchell Prize, a 1983 Right Livelihood Award (often called
the “alternative Nobel Prize”), the 1999 Lindbergh Award, and Time’s 2000
Heroes for the Planet Award. In 1989 he won the Onassis Foundation’s first
Delphi Prize, one of the world’s top environmental awards, for their “essential
contribution towards finding alternative solutions to energy problems.” That
contribution included the “end-use / least-cost” redefinition of the energy
problem (in Foreign Affairs in 1976)—asking what quantity, quality, scale, and
source of energy will do each task in the cheapest way. This economically based
approach first permitted successful foresight in the competitive energy-service
marketplace.
In
1993 he received the Nissan Prize for inventing superefficient
ultralight-hybrid cars, to which ~$10 billion had been committed by 2000, and
in 1999, partly for that work, the World Technology Award (Environment). He
also received the 1997 Heinz Award, the 2000 Happold Medal of the [UK]
Construction Industry Council, the 2005 Benjamin Franklin Medal of the [UK]
Royal Society of Arts (Life Fellow), and in 2007, the Blue Planet Prize, Volvo
Prize, honorary membership of the American Institute of Architects, Foreign
Membership of the Royal Swedish Academy of Engineering Sciences, Time
International’s Hero of the Environment award, Popular Mechanics’ Breakthrough
Leadership award, and honorary Senior Fellowship of the Design Futures Council.
In 2008 he was named one of America’s 24 Best Leaders by U.S. News & World
Report and Harvard’s Kennedy School, and received the first Aspen Institute /
National Geographic Energy and Environment Award for Individual Thought
Leadership. In 2009, he received the National Design Award (Design Mind), Time
named him among the world’s 100 most influential people, and Foreign Policy,
one of the 100 top global thinkers. In 2010, he was Runner-Up for the Zayed
Future Energy Prize.
In
1982, the Lovinses cofounded Rocky Mountain Institute, an independent,
entrepreneurial, nonprofit think-and-do tank. RMI’s ~80 staff drive the
efficient and restorative use of resources to help create a world thriving,
verdant, and secure, for all, for ever. Ms. Lovins left RMI in 2002; Mr. Lovins
is now RMI's Chairman and Chief Scientist. The Institute’s ~$13-million annual
revenue comes from programmatic enterprise, chiefly private-sector consultancy,
and from grants and donations. RMI’s balance sheet comes largely from Mr.
Lovins’s having cofounded, led, spun off, and in 1999 sold (to the Financial
Times group), E Source, the premier source of information on advanced electric
efficiency.
Mr.
Lovins led the energy design for his home (and RMI’s original headquarters),
whose ~99% savings in space- and water-heating energy (to –44°C or –47°F) and
~90% in home electricity paid back in ten months with 1983 technology. An
$18-million utility experiment he cofounded and -steered in the 1990s,
PG&E’s “ACT²,” validated his claim that very large energy savings could
cost less than small or no savings, e.g. in houses comfortable with no air
conditioner at up to +46ºC (+115°F) yet costing less to build. He founded and
until 2007 chaired RMI’s fourth spinoff, the advanced-composites technology
developer Fiberforge Corporation, and is RMI’s lead practitioner—lately helping
redesign >$30 billion worth of facilities in 29 sectors—in implementing for
major firms the tenets of natural capitalism, which shared the 2001 Shingo
Prize (Research), the “Nobel Prize for Manufacturing.” In 2004, he led a
Pentagon-cosponsored synthesis of how to eliminate U.S. oil use, led by
business for profit, and in 2007, became the first member of the Transformation
Advisory Council for the Executive Chairman of Ford Motor Company. His other
senior advisory relationships have lately served the leaders of Coca-Cola,
Deutsche Bank, Holcim, Interface, and Wal-Mart and of several startup firms.
Mr.
Lovins’s other clients have included Accenture, Allstate, AMD, Anglo American,
Anheuser-Busch, Bank of America, Baxter, Borg-Warner, BP, HP Bulmer, Carrier,
Chevron, Ciba-Geigy, CLSA, ConocoPhillips, Corning, Dow, Equitable, GM, HP,
Invensys, Lockheed Martin, Mitsubishi, Monsanto, Motorola, Norsk Hydro,
Petrobras, Prudential, Rio Tinto, Royal Dutch/Shell, Shearson Lehman Amex,
STMicroelectronics, Sun Oil, Suncor, Texas Instruments, UBS, Unilever,
Westinghouse, Xerox, major developers, and over 100 energy utilities. His
public-sector clients have included the OECD, the UN, and RFF; the Australian,
Canadian, Dutch, German, and Italian governments; 13 states; Congress; and the
U.S. Energy and Defense Departments.
Mr.
Lovins has briefed 21 heads of state, given expert testimony in eight countries
and 20+ states, delivered thousands of lectures, and written 31 books and more
than 450 papers, as well as poetry, landscape photography, music (he was a
pianist and composer), and an electronics patent. In 1980–81 he served on the
U.S. Department of Energy’s senior advisory board, and in 1999–2001 and
2006–08, on Defense Science Board task forces on military energy strategy. In
1984 he was elected a Fellow of the American Association for the Advancement of
Science “for his book Soft Energy Paths and many other noteworthy contributions
to energy policy,” in 1988, of the World Academy of Arts and Sciences, and in
2001, of the World Business Academy. Dr. Alvin Weinberg, former Director of Oak
Ridge National Laboratory, called him “surely the most articulate writer on
energy in the whole world today; "Newsweek, "one of the Western
world’s most influential energy thinkers.” Dr. John Ahearne, then Vice
President of Resources for the Future, remarked that “Amory Lovins has done
more to assemble and advance understanding of [energy] efficiency opportunities
than any other single person.” The Centennial Issue of The Wall Street Journal
named him among 39 people in the world most likely to change the course of
business in the 1990s; Car called him the 22nd most powerful person in the
global car industry; and The Economist wrote in 2008 that “history has proved
him right.”
An
occasional advisor to the National Association of Regulatory Utility
Commissioners, World Business Council for Sustainable Development, and Kleiner
Perkins Caufield & Byers, Mr. Lovins has addressed hundreds of fora
sponsored by such groups as The Engineering Foundation, Association of Energy
Engineers, ASHRAE, Society of Automotive Engineers, Royal Academy of
Engineering, National Academy of Sciences, American Physical Society,
International Association for Energy Economics, Montreux Energy Forum, Institution
of Electrical Engineers, McKinsey, Accenture, Merrill Lynch, JPMorgan, Allen
& Co., News Corporation, Fortune, Forbes, Time, ULI, IDRC, CoreNet, AIA,
API, AAPG, AGA, EEI, EPRI, CRIEPI, Hoover and Brookings Institutions, CSIS,
Chatham House, Council on Foreign Relations, Pacific Council, Commonwealth
Club, Keidanren, Conference Board, World Economic Forum, Tällberg Conference,
TED, FiRE, eg, World Bank, GBN, Highlands Forum, NPS, NWC, NDU, DAU, Aspen
Design Conference, Royal Society, and Royal Society of Arts. He collaborates on
landscape photography and orangutan conservation with his wife, fine-art
landscape photographer Judy Hill Lovins (www.judyhill.com).
World Class Supply carries eco-friendly building and lawn products!
World Class Supply carries eco-friendly building and lawn products!
4.17.2013
INTERVIEW: Building Science Pioneer Dr. Joe Lstiburek on
the Good, Bad and Ugly Side of Buildings
Posted By Andrew Michler On March 11, 2013
@ 12:05 am In Architecture,Interviews,Sustainable Building

The term ‘building science’ is used quite often now
in sustainable building circles, but much of what we understand of it
can be traced back to the work of Dr.
Joe Lstiburek [4], founder ofBuilding Science Corporation [5].
He is anything but your typical engineer [6] or scientist
who spends time crunching numbers or hiding away in a lab. Lstiburek has spent
most of his career out in the field, testing and examining what
works and what doesn’t. Many of the building standards today — from
building codes to ASHRE to testing methodology — have his finger prints
all over them, and his tough love criticism of
building design is undercut with his wry humor and, of course,
an encyclopedic knowledge of building construction. Read on to learn
where buildings go wrong and what we can do about it.
Inhabitat: What does building science really mean? Did it
not exist 50 years ago?
Joe Lstiburek: Well, it always existed. It’s
really the technical side of architecture [7] that
architects gave up. If architects did their job there wouldn’t be any need for
building science. You know, I’m flabbergasted by the architectural profession
giving up control of such a profitable part of the industry, which is the
interaction of the building enclosure with the climate and the people and the
mechanical system.
You know, this occurred because of the change in the focus
on the education of the architects, the school. They’re focused – they’re
trained in art. They’re not trained in physics and material science to actually
execute their designs.
Back in the day, 100 years ago, or maybe 50 years ago in
Europe, architects were trained like master builders. They understood
structure. They understood mechanical. They understood physics. They understood
material science. They understood how everything worked together. The focus now
on the architectural education is all art and what’s missing are all of those
other pieces — one of those missing pieces is building science or building
physics.
Inhabitat: Do they feel like it’s not their problem? Such
as how a building envelope will necessarily function in the real world — that
if it’s down on paper and it’s been done before, then that’s okay?
Joe Lstiburek: I can’t speak for the
architectural community, although I often try to – that is I think the
arrogance of the profession drives me crazy. I think they feel it’s beneath
their dignity to worry about these little, minor problems, like how to keep the
rain out of the building, how to keep the air in and the air out. Let somebody
else worry about that. I’m here to make an uplifting building to society to basically
send a message about how this building is going to make this place a better
place to live, and the people that live and work in it are better people.
That’s what my mission is. This other stuff somebody else will worry about.
Inhabitat: So how do you get them excited about building
science again?
Joe Lstiburek: Well, I don’t. What happens is
the legal profession does that for us. The most effective technology transfer
in the world is a lawsuit. They never call us when things are going well. They
call us, “Oh, my God! We’re getting our ass sued because this problem
occurred.”
Inhabitat: One of my favorite things you talk about
is how highrises eighty years ago were more energy efficient than just about
anything built today, especially with curtain walls and glass.
Joe Lstiburek: Well, it’s real easy. It’s just
glass. I mean we have glass boxes and glass and steel are inefficient. Back in
the day we had glazing ratios that were 10 and 15 percent and mass walls. An R2
curtain wall can’t compare to an R8 mass wall assembly. It’s not even close.
Inhabitat: So we talk about these advanced materials,
advanced glazing options we have now and, you know, they go on and on and on.
They are still nothing compared to a masonry wall as far as
energy efficiency?
Joe Lstiburek: They’re nothing to the old
approaches, but in the last 50 years the architectural profession has managed
to piss away every energy advance that the rest of us have made because of all
of the glass. I mean it’s just amazing to me.
And the hypocrisy is stunning. They blame everything. We’re
here to save the planet. We’re here because it’s real important for our carbon
footprint. And yet they turn out one glass box after another glass box after
another glass box and they’re interested in what the emission rate of the paint
is, and what the embodied energy of the carpet is, and the biggest problem is
their original design. That just drives me crazy. LEED [8] is
a colossal joke for that reason. They equate a bike rack with the same
efficiency as the enclosure.
Inhabitat: Everybody who wants to point LEED’s weakness
uses the bike rack argument.
Joe Lstiburek: Guess what? For good reason. And
you know what? They’re idiots to do that and they refuse to limit glazing
ratios and they don’t measure s***.
Inhabitat: And there’s no commissioning of the envelope.
Joe Lstiburek: No. It’s crazy, and you know
what? We’ve been collecting the numbers and they’re pathetic. What’s great is
that, okay, now they’re going to fix it, nothing like taking a really flawed
and screwed up program and having to fix it.
Well, the lawsuit
that Gifford started [9] gave them a wake-up call. The
fact that people are now publishing the results and they’re pretty poor has
given a wake-up call. At the end of the day, LEED is going to get fixed because
they have no choice. It’s just that we’ve wasted a decade.
Inhabitat: It wasn’t just that lawsuit. You really
started harping on how weak the LEED energy and atmosphere credits were in
2008.
Joe Lstiburek: I couldn’t understand why a
licensed engineer or a licensed architect would have an outside bunch with a
checklist supplement their professional knowledge and experience. I mean how
insulting is that? Because that tells me that you are so poor as a professional
that you believe that the judgment of a third-party checklist is more
significant than your knowledge.
And experience as an architect or engineer. Are you kidding
me? I mean I would have thrown them out of my office. I would have said, “What?
Get the hell out of here.”
You go and you do this checklist thing and you’re telling me
that I have to superimpose this arbitrarian, capricious checklist on my skill
as an architect, as an engineer. I mean that, to me, is flabbergasting.
Inhabitat: So is it the same effect of when architects
gave up the idea of building science and said somebody else can worry about it.
The LEED checklist gave the architects the opportunity for somebody else to
worry about what green building really is?
Joe Lstiburek: The architects have caused their
own problem and only the architects can solve their own problem and I have
faith that the architectural profession will fix itself. Architects need to get
in charge of the process again, totally in charge of the process, and for that
they need the education and the experience to do that.
There should be no reason that we have all of these outside
consultants that are sucking bits of the architectural key out of the process.
The architects should grab that for themselves and deliver the whole building
the right way, to be the boss of the job, to be the master builders again. I
mean my daughter is an architect and I keep telling them, “Your generation has
to fix this. You guys need to be in charge again.”

Inhabitat: We talked about the curtain wall or glass
being a key concern of energy efficiency in buildings. What else is a major
issue right now?
Joe Lstiburek: In my view, over-ventilation.
Inhabitat: Is that ASHRAE’s fault or just people are
doing above and beyond?
Joe Lstiburek: Well, ASHRAE is dominated by a
vested interest in politics and LEED is even worse, if you can imagine that. I
mean could you imagine getting a LEED point for increasing the ventilation 30
percent above ASHRAE and ASHRAE’s is already out of control.
The answer is source control, dilution is not the solution
to indoor pollution and increasing ventilation rates is a horrible problem. The
right way to do it is to not have the contaminant built into the building in
the first place. And despite all of the people saying that there’s a clear link
between certain levels of contaminants and medical effects, the epidemiology
hasn’t been done.
People claim that it’s been done, but believe it or not, we
don’t have the information in houses. We don’t know what the contaminants are.
They have not been measured carefully and we’re making national policy
decisions on ventilation going blind, with a bunch of people just getting
together and offering an opinion. And the opinion is based on which political
faction has managed to stack the ASHRE committee with their dominant voting
block.
That’s not the way to do this. I mean you’d think with the
amount of energy that buildings consume, and the amount of energy that
residential buildings consume, that maybe somebody, like the federal
government, would actually fund a study. You would need $20 million or $30
million and to go around and measure a whole slew of things in houses. That’s
not been done, but yet, changing the ventilation rate by 15 or 20 percent is
going to have more than that impact cost-wise on energy within the first year.
This kind of stuff drives me crazy. They manage to piss away
money on stupid s*** and they can’t seem to fund something that’s important.
And the same thing in commercial buildings. You know, people
are claiming that this level of formaldehyde [10] is
dangerous and this level isn’t. What’s all of this based on? I mean most of the
limits and for indoor air in buildings we’re simply taking occupational numbers
and dividing by ten. Why not dividing by 12? Why not dividing by 15? In
California, because California is crazy on every conceivable level, they
divide by 100 [11]. So, in one state the occupational
number because the indoor number by dividing by ten and California divided by
100. If people knew how arbitrary and capricious this was they’d go,
“Well, you’re kidding me.”
Inhabitat: Is California basing their numbers on European
models?
Joe Lstiburek: No. It wasn’t based on any
models. What’s amazing is formaldehyde in houses doesn’t respond to ventilation
rate changes. So if you’re ventilating at 0.1 versus 0.2 versus 0.3, the
formaldehyde concentration remains constant. The reason is the more you
ventilate the more it emits. You ventilate less it emits less. Don’t put it in
the building, that’s a phenomenally successful way of dealing with the problem.
I’ll give you another example, which will never happen, but
late at night I dream about it — have you’ve heard of the MSDS sheets?
Inhabitat: Sure.
Joe Lstiburek: They tell you absolutely nothing.
What people think that the MSDS sheets tells us is what the manufacturer puts
in their product. The answer is no. That would be useful if they told us
everything that went into this product and the quantities, but that’s viewed as
a trade secret.
What the MSDS sheet tells us is that if you put this into
the product, you have to tell us that it’s in the product and this comes from a
very short list of “this’es”. In other words, in order to get on that short
list it takes a lot of effort. It really has to be miserable and beyond a
shadow of a doubt, bad. So there’s a very short list of what you have to
notify.
What that means is that people are idiots to take anything
from that list, to put it in there. So they use a whole bunch of other things
that nobody knows anything about or haven’t made it to the list, but they don’t
have to tell you about it. I always laugh –LEED and other people
want you get to the MSDS sheet – and I’m saying “Why?” What you need to
do is you need to take one of the guys who makes this stuff out to dinner, get
him drunk, and ask him: “What’s in there?”
Inhabitat: Another study funding opportunity for the U.S.
government?
Joe Lstiburek: Well, not funding – basically,
change the law. Make them tell us what’s in their products.
Inhabitat: So that regulation would make complete sense?
Joe Lstiburek: Phenomenal sense. Tell us what’s
in it.
Inhabitat: Let’s get back to energy a little bit. Is
thermal bridging the next cusp of people’s thinking about how building
envelopes work?
Joe Lstiburek: Well, it’s no mystery to anybody
who knows about buildings that it’s a big deal. I’m kind of amused that people
are just figuring out well, glass is really bad and there’s too much it. Not
having insulation continuously is a big deal.
What’s even more important is that air tightness is even
more important. There’s no requirement for air tightness. How can you with a
straight face talk about energy efficiency and not have a requirement for air
tightness?
Inhabitat: How would you test for air tightness in a
large building?
Joe Lstiburek: It’s easy. Every building has a
mechanical system. You just simply open all of the interior doors and turn on
the exhaust fan and measure the pressure difference, then close the exhaust fan
and turn on the supply fan and measure the pressure difference. You got your
entire building leakage.
You don’t even need to do it that way. Just simply take a
compartment and measure the pressure in the compartment. You don’t have to
measure the whole building, just measure pieces of the building. There are a
lot of ways to do this.
I wrote about it in Understanding
Air Barriers [12] on our web site and actually did
my doctoral dissertation on how some of this can be done. It’s just that it
takes about a half a day to set up the test and about 15 minutes to run the
test. For people that claim that this is complicated and hard, it’s just not
hard.
The problem is that because it is easy to do, and if you
actually do it and you create a performance requirement, people will have to
meet that requirement. That means they’re going to have to change what they do
and that’s what the problem is; people don’t want to change what they do.
Inhabitat: You have been successful in taking complex
building dynamics and making them relatively simple to understand. Do you think
that building science is less complicated than a lot of folks out there are
making it sound with a lot of hemming and hawing?
Joe Lstiburek: It’s a lot less complicated than
people say and my only observation is there’s a lot of money to be made in
keeping the peasants confused. I mean it’s so easy. What drives me crazy is
WUFI models and computer simulations. None of that is necessary, and most of it
is done wrong anyway.
I spend most of my time, and my firm spends a lot of time
debunking other people’s reports, saying, “You can’t possibly be saying this
based on what you did. The problem is the wall is leaking because you don’t
have a flashing. Your hygrothermal model has nothing to do with why this wall
is wet.”
Inhabitat: They couldn’t see the trees for the
forest.
Joe Lstiburek: They couldn’t see the water
through the trees.
Inhabitat: There you go. It sounds like, especially when
we start talking about air barriers, you just do that right than you solve a
lot of the other problems. You made a good living on buildings having lots of
moisture issues.
Joe Lstiburek: It’s been a hell of a good life.
I get to spend the entire winter in Aspen. Are you kidding me? The key to
spending your entire winter in Aspen is to find a woman to love and marry, stay
married to her, and get into fixing buildings. You need both.
Inhabitat: Good advice for the upcoming engineers who
read this. So what’s the take away? Is it that air barriers are the biggest
thing we need to focus on?
Joe Lstiburek: Well, no. Look, if I was in
charge of teaching architects building
science becomes very simple [13]. Building enclosure is an
environmental separator. You want to keep the outside out and the inside in,
except when you want to bring the outside in and when you want to have the
inside out. That’s it and there are certain rules on how to do that.
I have this little list of rules and it all can be distilled
into we need a water controlled barrier, an air controlled barrier, a vapor
controlled barrier, and a thermal controlled barrier. Then we need a method of
exchanging the inside with the outside based on when we want to. That’s it,
there are sub-rules on how you do this, but that’s fundamentally it.
And I would have loved to written my own LEED standard. It
would have been a paragraph long and it would start off by saying, “Don’t do
stupid things,” and, “Do this,” and we’re done. “And measure everything,”
because if you can’t measure it, I don’t believe it.
Inhabitat: Are we looking at a climate specific
design?
Joe Lstiburek: Oh, I don’t believe that. The
wall-roof foundation assembly that I laid out works everywhere.
If you are doing poor assemblies you have to be very careful
climatically, but a good assembly works everywhere. The irony is that the
crappy assemblies are very climatically sensitive. The good assemblies are
climatically robust.
Inhabitat: So, does that mean state-of-the art is that we
can find wall systems that can be translated to work in almost any situation.
Joe Lstiburek: I have a little bit of fun with
this. I teach at the university now and I no longer fail stupid students
because that would be discriminating against stupid students. I say, “Look, I
have to pass you. You’re an idiot. I can’t fail you, but I’ll make a deal.
Promise me this – that regardless of where you end up and how long you
practice, you’re only going to use this wall design, and this roof design, and
this foundation design, because they work everywhere.”
Inhabitat: And forever.
Joe Lstiburek: And forever. Quite frankly, that
is true.
Inhabitat: So you feel confident that building science is
at the point now that we can build a quality envelope that we’ll feel
comfortable with 40 years from now. We go back, we tear that thing up, we’ll
feel that everything’s done what it needs to?
Joe Lstiburek: Oh, we were able to do that 50,
60 years ago. The answer is yes, we’re able to do that now and we were able to
do that before I was born. The irony is that even though that information has
been known for so long, it’s not been used. And my observation on that is that
people don’t use stuff until it becomes impossible for them to not use it. In
other words, things become intolerably bad before there’s a change or an
intervention. It’s only recently that things are becoming intolerably bad
enough that we have to intervene and fix, even though we knew or some folks
knew how to avoid the problems 50 or 60 years ago.
None of this is very complicated, none of this is a big
mystery. What’s happening now is that we need to get this information into the
people who need to make the decisions in an informed matter. In other words,
people aren’t inherently bad. They just don’t have the information they need at
the right time to make the right decision. So this is an information issue as
opposed to a research issue. We don’t need to do anymore research. We need to
do better transfer of what we know to the people who need to make the decisions
at the right time.
Inhabitat: So where is that information now? What are the
sources for working professionals to tap into this in a meaningful way?
Joe Lstiburek: Well, NIBS, National Institute for Building Science [14] has
got a group called BETEC [15] and
they’ve got some phenomenal design stuff online. I mean I hate to brag, but our
website BuildingScience.com [16] is
pretty darn good. And it’s for free –actually not, you’ve already paid for
it. A lot of that work came out of government contracts that we were paid
to do.
The National
Research Council of Canada [17] and Canada Mortgage and
Housing Corporation [18] have fabulous information
online. The Department
of Energy [19], USDoE, has got phenomenally good
information online. And by and large, it’s fairly consistent. There aren’t big
differences and wherever there is a big difference, just agree with me.
Inhabitat: Very good.
Joe Lstiburek: That was a bit of humor there,
but you’re not laughing.
Inhabitat: I’ll write, “Ha-ha,” in there.
Joe Lstiburek: The big questions have been
answered consistently well by all of these groups and there are issues in the
margins, but they’re not big issues.
Inhabitat: When you go on the DoE web site there’s like
400 links or something like that to the energy software available, energy
modeling software, for instance. Now, is any of this stuff really –
Joe Lstiburek: Useful? No. No. No.
Inhabitat: Everybody is wishing to have that magic bullet
software?
Joe Lstiburek: Well, I view it as in love with
Star Trek. I blame it all on Star Trek. Spock could go into that shuttle bay
with his tricorder, do a tricorder scan and figure out that the tachyon field
was interfering with the dilythiam crystals, causing him to off-gas, which is
why Uhura has a headache. F**k that. We can’t measure s**t like that, but we
believe that we can measure everything.
Watch NCIS and Abby Sciuto, that babe in the lab – you know,
freaking does magical things and measures s**t and she does it all in 45
minutes, not counting commercials. It’s that we couldn’t do in 20 years even if
we had unlimited money and people think that you can simulate and measure
stuff. The world is not that clean and neat.
The best way we learn all of this is to build it and you see
what happened. You say, “Ah, this worked. This didn’t,” and that’s the best
education or information. That information lies in the experience base of the
older engineers, architects and contractors.
One of the biggest problems we have is what I call our own
institutional memory. We do a lousy job in construction, engineering and
architecture, passing on the lessons of one generation to the next. So we are
this huge, dysfunctional family. We need a Dr. Phil to get us all to talk to one
another, or an Oprah, or somebody.
Inhabitat: It’s amazing how many times you refer to the
fact that you would hypothesize something, come up with it and find it – it was
in the books in the ‘50s and the ‘40s and the ‘60s.
Joe Lstiburek: It’s funny. I am one of the most
frustrated, egotistical engineers on the planet. I thought I was a clever,
smart guy who figured out stuff and it turns out that nothing I’ve ever thought
I figured out did I actually figure out. It had been already done – better,
earlier, more elegantly by not just one person, by lots of people. And we’re
having all of these same discussions and arguments over and over and over
again.
You know what? I feel like Bill Murray in Groundhog’s Day,
except I don’t have an Andie MacDowell.
Locate Sustainable Building Materials at WorldClassSupply
Locate Sustainable Building Materials at WorldClassSupply
2.28.2013
The What and Why of Passive House (PassivHaus) Design in a nutshell according to Wikipedia.com…..
While some techniques and technologies were specifically developed
for the Passive House standard, others, such as superinsulation, already existed, and the concept of passive solar
building design dates back to
antiquity.
Standards
The Passivhaus standard for central Europe requires that the
building fulfills the following requirements:
- The building must be designed
to have an annual heating demand as calculated with the Passivhaus
Planning Package of not more than 15 kWh/m²
per year (4746 btu/ft²
per year) in heating and 15 kWh/m²
per year cooling energy OR to be designed with a peak heat load of 10W/m²
- Total primary energy (source
energy for electricity and etc.) consumption (primary energy for heating, hot water andelectricity) must not be more than 120 kWh/m² per year (3.79 × 104 btu/ft²
per year)
- The building must not leak more
air than 0.6 times the house volume per hour (n50 ≤ 0.6 /
hour) at 50 Pa (N/m²)
as tested by a blower door
Recommendations
- Further, the specific heat load
for the heating source at design temperature is recommended, but not
required, to be less than 10 W/m²
(3.17 btu/h.ft²
per hour).
These standards are much higher than houses built to most normal
building codes. For comparisons, see the international comparisons
section below.
National partners within the 'consortium for the Promotion of
European Passive Houses' are thought to have some flexibility to adapt these
limits locally.[24]
Space heating requirement
By achieving the Passivhaus standards, qualified buildings are
able to dispThe What and Why of Passive House (PassivHaus) Design in a nutshell according to Wikipedia.com…..
While some techniques and technologies were specifically developed for the Passive House standard, others, such as superinsulation, already existed, and the concept of passive solar building design dates back to antiquity.
Standards
The Passivhaus standard for central Europe requires that the building fulfills the following requirements:
• The building must be designed to have an annual heating demand as calculated with the Passivhaus Planning Package of not more than 15 kWh/m² per year (4746 btu/ft² per year) in heating and 15 kWh/m² per year cooling energy OR to be designed with a peak heat load of 10W/m²
• Total primary energy (source energy for electricity and etc.) consumption (primary energy for heating, hot water andelectricity) must not be more than 120 kWh/m² per year (3.79 × 104 btu/ft² per year)
• The building must not leak more air than 0.6 times the house volume per hour (n50 ≤ 0.6 / hour) at 50 Pa (N/m²) as tested by a blower door
Recommendations
• Further, the specific heat load for the heating source at design temperature is recommended, but not required, to be less than 10 W/m² (3.17 btu/h.ft² per hour).
These standards are much higher than houses built to most normal building codes. For comparisons, see the international comparisons section below.
National partners within the 'consortium for the Promotion of European Passive Houses' are thought to have some flexibility to adapt these limits locally.[24]
Space heating requirement
By achieving the Passivhaus standards, qualified buildings are able to dispense with conventional heating systems. While this is an underlying objective of the Passivhaus standard, some type of heating will still be required and most Passivhaus buildings do include a system to provide supplemental space heating. This is normally distributed through the low-volume heat recovery ventilation system that is required to maintain air quality, rather than by a conventional hydronic or high-volume forced-air heating system, as described in the space heating section below.
Construction costs
In Passivhaus buildings, the cost savings from dispensing with the conventional heating system can be used to fund the upgrade of the building envelope and the heat recovery ventilation system. With careful design and increasing competition in the supply of the specifically designed Passivhaus building products, in Germany it is now possible to construct buildings for the same cost as those built to normal German building standards, as was done with the Passivhaus apartments at Vauban, Freiburg.[25]On average, however, passive houses are still up to 14% more expensive upfront than conventional buildings.[26]
Evaluations have indicated that while it is technically possible, the costs of meeting the Passivhaus standard increase significantly when building in Northern Europe above 60° latitude.[27][28] European cities at approximately 60° include Helsinki in Finland and Bergen in Norway. London is at 51°; Moscow is at 55°.
These facts have led a number of architects to construct buildings that use the ground under the building for massive heat storage to shift heat production from the winter to the summer. Some buildings can also shift cooling from the summer to the winter. At least one designer uses a passive thermosiphon carrying only air, so the process can be accomplished without expensive, unreliable machinery.[29] (See also Annualized geo solar)
Design and construction
The Passivhaus uses a combination oflow-energy building techniques and technologies.
Achieving the major decrease in heating energy consumption required by the standard involves a shift in approach to building design and construction. Design may be assisted by use of the 'Passivhaus Planning Package' (PHPP),[30] which uses specifically designed computer simulations.
To achieve the standards, a number of techniques and technologies are used in combination:[2]
Passive solar design and landscape
Passive solar building design and energy-efficient landscaping support the Passive house energy conservation and can integrate them into a neighborhood and environment. Following passive solar building techniques, where possible buildings are compact in shape to reduce their surface area, with principal windows oriented towards the equator - south in the northern hemisphere and north in the southern hemisphere - to maximize passive solar gain. However, the use of solar gain, especially in temperate climate regions, is secondary to minimizing the overall house energy requirements. In climates and regions needing to reduce excessive summer passive solar heat gain, whether from direct or reflected sources, Brise soleil, trees, attached pergolas with vines, vertical gardens, green roofs, and other techniques are implemented.
Passive houses can be constructed from dense or lightweight materials, but some internal thermal mass is normally incorporated to reduce summer peak temperatures, maintain stable winter temperatures, and prevent possible overheating in spring or autumn before the higher sun angle "shades" mid-day wall exposure and window penetration. Exterior wall color, when the surface allows choice, for reflection or absorption insolation qualities depends on the predominant year-round ambient outdoor temperature. The use of deciduous trees and wall trellised or self attaching vines can assist in climates not at the temperature extremes.
Superinsulation
Passivhaus buildings employ superinsulation to significantly reduce the heat transfer through the walls, roof and floor compared to conventional buildings.[31] A wide range ofthermal insulation materials can be used to provide the required high R-values (low U-values, typically in the 0.10 to 0.15 W/(m².K) range). Special attention is given to eliminating thermal bridges.
A disadvantage resulting from the thickness of wall insulation required is that, unless the external dimensions of the building can be enlarged to compensate, the internal floor area of the building may be less compared to traditional construction.
In Sweden, to achieve passive house standards, the insulation thickness would be 335 mm (about 13 in) (0.10 W/(m².K)) and the roof 500 mm (about 20 in) (U-value 0.066 W/(m².K)).
Advanced window technology
Typical Passive House windows
To meet the requirements of the Passivhaus standard, windows are manufactured with exceptionally high R-values (low U-values, typically 0.85 to 0.70 W/(m².K) for the entire window including the frame). These normally combine triple-paneinsulated glazing (with a good solar heat-gain coefficient,[2][31] low-emissivity coatings, sealed argon or krypton gas filled inter-pane voids, and 'warm edge' insulating glass spacers) with air-seals and specially developed thermally broken window frames.
In Central Europe and most of the United States, for unobstructed south-facing Passivhaus windows, the heat gains from the sun are, on average, greater than the heat losses, even in mid-winter.
Airtightness
Building envelopes under the Passivhaus standard are required to be extremely airtight compared to conventional construction. This is achieved through air barriers, careful sealing of every construction joint in the building envelope, and sealing of all service penetrations.[31]
Airtightness minimizes the amount of warm — or cool — air that can pass through the structure, enabling the mechanical ventilation system to recover the heat before discharging the air externally.[2]
Ventilation
Use of passive natural ventilation is an integral component of passive house design where ambient temperature is conducive — either by singular or cross ventilation; by a simple opening or enhanced by the stack effect from smaller ingress with larger egress windows and/or clerestory-operable skylight.
When ambient climate is not conducive, mechanical heat recovery ventilation systems, with a heat recovery rate of over 80% and high-efficiency electronically commutated motors (ECM), are employed to maintain air quality, and to recover sufficient heat to dispense with a conventional central heating system.[2] Since passively designed buildings are essentially air-tight, the rate of air change can be optimized and carefully controlled at about 0.4 air changes per hour. All ventilation ducts are insulated and sealed against leakage.
Some Passivhaus builders promote the use of earth warming tubes (typically ≈200 mm (~7,9 in) diameter, ≈40 m (~130 ft) long at a depth of ≈1.5 m (~5 ft)). These are buried in the soil to act as earth-to-air heat exchangers and pre-heat (or pre-cool) the intake air for the ventilation system. In cold weather the warmed air also prevents ice formation in the heat recovery system's heat exchanger. Concerns about this technique have arisen in some climates due to problems with condensation and mold.[32]
Alternatively, an earth to air heat exchanger can use a liquid circuit instead of an air circuit, with a heat exchanger (battery) on the supply air.
Space heating
Passivhaus: In addition to the heat exchanger (centre), a micro-heat pump extracts heat from the exhaust air (left) and hot water heats the ventilation air (right). The ability to control building temperature using only the normal volume of ventilation air is fundamental.
In addition to using passive solar gain, Passivhaus buildings make extensive use of their intrinsic heat from internal sources—such as waste heat from lighting, white goods (major appliances) and other electrical devices (but not dedicated heaters)—as well as body heat from the people and other animals inside the building. This is due to the fact that people, on average, emit heat equivalent to 100 watts each of radiated thermal energy.
Together with the comprehensive energy conservation measures taken, this means that a conventional central heatingsystem is not necessary, although they are sometimes installed due to client skepticism.[33]
Instead, Passive houses sometimes have a dual purpose 800 to 1,500 watt heating and/or cooling element integrated with the supply air duct of the ventilation system, for use during the coldest days. It is fundamental to the design that all the heat required can be transported by the normal low air volume required for ventilation. A maximum air temperature of 50 °C (122 °F) is applied, to prevent any possible smell of scorching from dust that escapes the filters in the system.
The air-heating element can be heated by a small heat pump, by direct solar thermal energy, annualized geothermal solar, or simply by a natural gas or oil burner. In some cases a micro-heat pump is used to extract additional heat from the exhaust ventilation air, using it to heat either the incoming air or the hot water storage tank. Small wood-burning stoves can also be used to heat the water tank, although care is required to ensure that the room in which stove is located does not overheat.
Beyond the recovery of heat by the heat recovery ventilation unit, a well designed Passive house in the European climate should not need any supplemental heat source if the heating load is kept under 10W/m².[34]
Because the heating capacity and the heating energy required by a passive house both are very low, the particular energy source selected has fewer financial implications than in a traditional building, although renewable energy sources are well suited to such low loads.
Lighting and electrical appliances
See also: Daylighting, Passive daylighting, Active daylighting, and Ecological footprint
To minimize the total primary energy consumption, the many passive and active daylighting techniques are the first daytime solution to employ. For low light level days, non-daylighted spaces, and nighttime; the use of creative-sustainable lighting design using low-energy sources such as 'standard voltage' compact fluorescent lamps and solid-state lighting with Light-emitting diode-LED lamps, organic light-emitting diodes, and PLED - polymer light-emitting diodes; and 'low voltage' electrical filament-Incandescent light bulbs, and compact Metal halide, Xenon and Halogen lamps, can be used.
Solar powered exterior circulation, security, and landscape lighting - with photovoltaic cells on each fixture or connecting to a central Solar panel system, are available forgardens and outdoor needs. Low voltage systems can be used for more controlled or independent illumination, while still using less electricity than conventional fixtures and lamps. Timers, motion detection and natural light operation sensors reduce energy consumption, and light pollution even further for a Passivhaus setting.
Appliance consumer products meeting independent energy efficiency testing and receiving Ecolabel certification marks for reduced electrical-'natural-gas' consumption and product manufacturing carbon emission labels are preferred for use in Passive houses. The ecolabel certification marks of Energy Star and EKOenergy are examples.
Traits of passive houses
Typically, passive houses feature:
• Fresh, clean air: Note that for the parameters tested, and provided the filters (minimum F6) are maintained, HEPA quality air is provided. 0.3 air changes per hour (ACH) are recommended, otherwise the air can become "stale" (excess CO2, flushing of indoor air pollutants) and any greater, excessively dry (less than 40% humidity). This implies careful selection of interior finishes and furnishings, to minimize indoor air pollution from VOC's (e.g., formaldehyde). This can be counteracted somewhat by opening a window for a very brief time, by plants, and by indoor fountains.
• Because of the high resistance to heat flow (high R-value insulation), there are no "outside walls" which are colder than other walls.
• Homogeneous interior temperature: it is impossible to have single rooms (e.g. the sleeping rooms) at a different temperature from the rest of the house. Note that the relatively high temperature of the sleeping areas is physiologically not considered desirable by some building scientists. Bedroom windows can be cracked open slightly to alleviate this when necessary.
• Slow temperature changes: with ventilation and heating systems switched off, a passive house typically loses less than 0.5 °C (1 °F) per day (in winter), stabilizing at around 15 °C (59 °F) in the central European climate.
• Quick return to normal temperature: opening windows or doors for a short time has only a limited effect; after aperatures are closed, the air very quickly returns to the "normal" temperature.
, others, such as superinsulation, already existed, and the concept of passive solar building design dates back to antiquity.
[edit]Standards
The Passivhaus standard for central Europe requires that the building fulfills the following requirements:[22][23]
The building must be designed to have an annual heating demand as calculated with the Passivhaus Planning Package of not more than 15 kWh/m² per year (4746 btu/ft² per year) in heating and 15 kWh/m² per year cooling energy OR to be designed with a peak heat load of 10W/m²
Total primary energy (source energy for electricity and etc.) consumption (primary energy for heating, hot water and electricity) must not be more than 120 kWh/m² per year (3.79 × 104 btu/ft² per year)
The building must not leak more air than 0.6 times the house volume per hour (n50 ≤ 0.6 / hour) at 50 Pa (N/m²) as tested by a blower door
Recommendations
Further, the specific heat load for the heating source at design temperature is recommended, but not required, to be less than 10 W/m² (3.17 btu/h.ft² per hour).
These standards are much higher than houses built to most normal building codes. For comparisons, see the international comparisons section below.
National partners within the 'consortium for the Promotion of European Passive Houses' are thought to have some flexibility to adapt these limits locally.[24]
Space heating requirement
By achieving the Passivhaus standards, qualified buildings are able to dispense with conventional heating systems. While this is an underlying objective of the Passivhaus standard, some type of heating will still be required and most Passivhaus buildings do include a system to provide supplemental space heating. This is normally distributed through the low-volume heat recovery ventilation system that is required to maintain air quality, rather than by a conventional hydronic or high-volume forced-air heating system, as described in the space heating section below.
Construction costs
In Passivhaus buildings, the cost savings from dispensing with the conventional heating system can be used to fund the upgrade of the building envelope and the heat recovery ventilation system. With careful design and increasing competition in the supply of the specifically designed Passivhaus building products, in Germany it is now possible to construct buildings for the same cost as those built to normal German building standards, as was done with the Passivhaus apartments at Vauban, Freiburg.[25] On average, however, passive houses are still up to 14% more expensive upfront than conventional buildings.[26]
Evaluations have indicated that while it is technically possible, the costs of meeting the Passivhaus standard increase significantly when building in Northern Europe above 60° latitude.[27][28] European cities at approximately 60° include Helsinki in Finland and Bergen in Norway. London is at 51°; Moscow is at 55°.
These facts have led a number of architects to construct buildings that use the ground under the building for massive heat storage to shift heat production from the winter to the summer. Some buildings can also shift cooling from the summer to the winter. At least one designer uses a passive thermosiphon carrying only air, so the process can be accomplished without expensive, unreliable machinery.[29] (See also Annualized geo solar)
Design and construction
The Passivhaus uses a combination of low-energy building techniques and technologies.
Achieving the major decrease in heating energy consumption required by the standard involves a shift in approach to building design and construction. Design may be assisted by use of the 'Passivhaus Planning Package' (PHPP),[30] which uses specifically designed computer simulations.
To achieve the standards, a number of techniques and technologies are used in combination:[2]
Passive solar design and landscape
Passive solar building design and energy-efficient landscaping support the Passive house energy conservation and can integrate them into a neighborhood and environment. Following passive solar building techniques, where possible buildings are compact in shape to reduce their surface area, with principal windows oriented towards the equator - south in the northern hemisphere and north in the southern hemisphere - to maximize passive solar gain. However, the use of solar gain, especially in temperate climate regions, is secondary to minimizing the overall house energy requirements. In climates and regions needing to reduce excessive summer passive solar heat gain, whether from direct or reflected sources, trees, attached pergolas with vines, vertical gardens, green roofs, and other techniques are implemented.
Passive houses can be constructed from dense or lightweight materials, but some internal thermal mass is normally incorporated to reduce summer peak temperatures, maintain stable winter temperatures, and prevent possible overheating in spring or autumn before the higher sun angle "shades" mid-day wall exposure and window penetration. Exterior wall color, when the surface allows choice, for reflection or absorption insolation qualities depends on the predominant year-round ambient outdoor temperature. The use of deciduous trees and wall trellised or self attaching vines can assist in climates not at the temperature extremes.
Superinsulation
Passivhaus buildings employ superinsulation to significantly reduce the heat transfer through the walls, roof and floor compared to conventional buildings.[31] A wide range of thermal insulation materials can be used to provide the required high R-values (low U-values, typically in the 0.10 to 0.15 W/(m².K) range). Special attention is given to eliminating thermal bridges.
A disadvantage resulting from the thickness of wall insulation required is that, unless the external dimensions of the building can be enlarged to compensate, the internal floor area of the building may be less compared to traditional construction.
In Sweden, to achieve passive house standards, the insulation thickness would be 335 mm (about 13 in) (0.10 W/(m².K)) and the roof 500 mm (about 20 in) (U-value 0.066 W/(m².K)).
Advanced window technology
Typical Passive House windows
To meet the requirements of the Passivhaus standard, windows are manufactured with exceptionally high R-values (low U-values, typically 0.85 to 0.70 W/(m².K) for the entire window including the frame). These normally combine triple-pane insulated glazing (with a good solar heat-gain coefficient,[2][31] low-emissivity coatings, sealed argon or krypton gas filled inter-pane voids, and 'warm edge' insulating glass spacers) with air-seals and specially developed thermally broken window frames.
In Central Europe and most of the United States, for unobstructed south-facing Passivhaus windows, the heat gains from the sun are, on average, greater than the heat losses, even in mid-winter.
Airtightness
Building envelopes under the Passivhaus standard are required to be extremely airtight compared to conventional construction. This is achieved through air barriers, careful sealing of every construction joint in the building envelope, and sealing of all service penetrations.[31]
Airtightness minimizes the amount of warm — or cool — air that can pass through the structure, enabling the mechanical ventilation system to recover the heat before discharging the air externally.[2]
[edit]Ventilation
Use of passive natural ventilation is an integral component of passive house design where ambient temperature is conducive — either by singular or cross ventilation; by a simple opening or enhanced by the stack effect from smaller ingress with larger egress windows and/or clerestory-operable skylight.
When ambient climate is not conducive, mechanical heat recovery ventilation systems, with a heat recovery rate of over 80% and high-efficiency electronically commutated motors (ECM), are employed to maintain air quality, and to recover sufficient heat to dispense with a conventional central heating system.[2] Since passively designed buildings are essentially air-tight, the rate of air change can be optimized and carefully controlled at about 0.4 air changes per hour. All ventilation ducts are insulated and sealed against leakage.
Some Passivhaus builders promote the use of earth warming tubes (typically ≈200 mm (~7,9 in) diameter, ≈40 m (~130 ft) long at a depth of ≈1.5 m (~5 ft)). These are buried in the soil to act as earth-to-air heat exchangers and pre-heat (or pre-cool) the intake air for the ventilation system. In cold weather the warmed air also prevents ice formation in the heat recovery system's heat exchanger. Concerns about this technique have arisen in some climates due to problems with condensation and mold.[32]
Alternatively, an earth to air heat exchanger can use a liquid circuit instead of an air circuit, with a heat exchanger (battery) on the supply air.
Space heating
Passivhaus: In addition to the heat exchanger (centre), a micro-heat pump extracts heat from the exhaust air (left) and hot water heats the ventilation air (right). The ability to control building temperature using only the normal volume of ventilation air is fundamental.
In addition to using passive solar gain, Passivhaus buildings make extensive use of their intrinsic heat from internal sources—such as waste heat from lighting, white goods (major appliances) and other electrical devices (but not dedicated heaters)—as well as body heat from the people and other animals inside the building. This is due to the fact that people, on average, emit heat equivalent to 100 watts each of radiated thermal energy.
Together with the comprehensive energy conservation measures taken, this means that a conventional central heating system is not necessary, although they are sometimes installed due to client skepticism.[33]
Instead, Passive houses sometimes have a dual purpose 800 to 1,500 watt heating and/or cooling element integrated with the supply air duct of the ventilation system, for use during the coldest days. It is fundamental to the design that all the heat required can be transported by the normal low air volume required for ventilation. A maximum air temperature of 50 °C (122 °F) is applied, to prevent any possible smell of scorching from dust that escapes the filters in the system.
The air-heating element can be heated by a small heat pump, by direct solar thermal energy, annualized geothermal solar, or simply by a natural gas or oil burner. In some cases a micro-heat pump is used to extract additional heat from the exhaust ventilation air, using it to heat either the incoming air or the hot water storage tank. Small wood-burning stoves can also be used to heat the water tank, although care is required to ensure that the room in which stove is located does not overheat.
Beyond the recovery of heat by the heat recovery ventilation unit, a well designed Passive house in the European climate should not need any supplemental heat source if the heating load is kept under 10W/m².[34]
Because the heating capacity and the heating energy required by a passive house both are very low, the particular energy source selected has fewer financial implications than in a traditional building, although renewable energy sources are well suited to such low loads.
[edit]Lighting and electrical appliances
See also: Daylighting, Passive daylighting, Active daylighting, and Ecological footprint
To minimize the total primary energy consumption, the many passive and active daylighting techniques are the first daytime solution to employ. For low light level days, non-daylighted spaces, and nighttime; the use of creative-sustainable lighting design using low-energy sources such as 'standard voltage' compact fluorescent lamps and solid-state lighting with Light-emitting diode-LED lamps, organic light-emitting diodes, and PLED - polymer light-emitting diodes; and 'low voltage' electrical filament-Incandescent light bulbs, and compact Metal halide, Xenon and Halogen lamps, can be used.
Solar powered exterior circulation, security, and landscape lighting - with photovoltaic cells on each fixture or connecting to a central Solar panel system, are available for gardens and outdoor needs. Low voltage systems can be used for more controlled or independent illumination, while still using less electricity than conventional fixtures and lamps. Timers, motion detection and natural light operation sensors reduce energy consumption, and light pollution even further for a Passivhaus setting.
Appliance consumer products meeting independent energy efficiency testing and receiving Ecolabel certification marks for reduced electrical-'natural-gas' consumption and product manufacturing carbon emission labels are preferred for use in Passive houses. The ecolabel certification marks of Energy Star and EKOenergy are examples.
Traits of passive houses
Typically, passive houses feature:
Fresh, clean air: Note that for the parameters tested, and provided the filters (minimum F6) are maintained, HEPA quality air is provided. 0.3 air changes per hour (ACH) are recommended, otherwise the air can become "stale" (excess CO2, flushing of indoor air pollutants) and any greater, excessively dry (less than 40% humidity). This implies careful selection of interior finishes and furnishings, to minimize indoor air pollution from VOC's (e.g., formaldehyde). This can be counteracted somewhat by opening a window for a very brief time, by plants, and by indoor fountains.
Because of the high resistance to heat flow (high R-value insulation), there are no "outside walls" which are colder than other walls.
Homogeneous interior temperature: it is impossible to have single rooms (e.g. the sleeping rooms) at a different temperature from the rest of the house. Note that the relatively high temperature of the sleeping areas is physiologically not considered desirable by some building scientists. Bedroom windows can be cracked open slightly to alleviate this when necessary.
Slow temperature changes: with ventilation and heating systems switched off, a passive house typically loses less than 0.5 °C (1 °F) per day (in winter), stabilizing at around 15 °C (59 °F) in the central European climate.
Quick return to normal temperature: opening windows or doors for a short time has only a limited effect; after aperatures are closed, the air very quickly returns to the "normal" temperature.
Standards
The Passivhaus standard for central Europe requires that the building fulfills the following requirements:[22][23]
• The building must be designed to have an annual heating demand as calculated with the Passivhaus Planning Package of not more than 15 kWh/m² per year (4746 btu/ft² per year) in heating and 15 kWh/m² per year cooling energy OR to be designed with a peak heat load of 10W/m²
• Total primary energy (source energy for electricity and etc.) consumption (primary energy for heating, hot water andelectricity) must not be more than 120 kWh/m² per year (3.79 × 104 btu/ft² per year)
• The building must not leak more air than 0.6 times the house volume per hour (n50 ≤ 0.6 / hour) at 50 Pa (N/m²) as tested by a blower door
Recommendations
• Further, the specific heat load for the heating source at design temperature is recommended, but not required, to be less than 10 W/m² (3.17 btu/h.ft² per hour).
These standards are much higher than houses built to most normal building codes. For comparisons, see the international comparisons section below.
National partners within the 'consortium for the Promotion of European Passive Houses' are thought to have some flexibility to adapt these limits locally
Space heating requirement
By achieving the Passivhaus standards, qualified buildings are able to dispense with conventional heating systems. While this is an underlying objective of the Passivhaus standard, some type of heating will still be required and most Passivhaus buildings do include a system to provide supplemental space heating. This is normally distributed through the low-volume heat recovery ventilation system that is required to maintain air quality, rather than by a conventional hydronic or high-volume forced-air heating system, as described in the space heating section below.
Construction costs
In Passivhaus buildings, the cost savings from dispensing with the conventional heating system can be used to fund the upgrade of the building envelope and the heat recovery ventilation system. With careful design and increasing competition in the supply of the specifically designed Passivhaus building products, in Germany it is now possible to construct buildings for the same cost as those built to normal German building standards, as was done with the Passivhaus apartments at Vauban, Freiburg.[25]On average, however, passive houses are still up to 14% more expensive upfront than conventional buildings.[26]
Evaluations have indicated that while it is technically possible, the costs of meeting the Passivhaus standard increase significantly when building in Northern Europe above 60° latitude.[27][28] European cities at approximately 60° include Helsinki in Finland and Bergen in Norway. London is at 51°; Moscow is at 55°.
These facts have led a number of architects to construct buildings that use the ground under the building for massive heat storage to shift heat production from the winter to the summer. Some buildings can also shift cooling from the summer to the winter. At least one designer uses a passive thermosiphon carrying only air, so the process can be accomplished without expensive, unreliable machinery.[29] (See also Annualized geo solar
Design and construction
The Passivhaus uses a combination oflow-energy building techniques and technologies.
Achieving the major decrease in heating energy consumption required by the standard involves a shift in approach to building design and construction. Design may be assisted by use of the 'Passivhaus Planning Package' (PHPP),[30] which uses specifically designed computer simulations.
To achieve the standards, a number of techniques and technologies are used in combination
[Passive solar design and landscape
Passive solar building design and energy-efficient landscaping support the Passive house energy conservation and can integrate them into a neighborhood and environment. Following passive solar building techniques, where possible buildings are compact in shape to reduce their surface area, with principal windows oriented towards the equator - south in the northern hemisphere and north in the southern hemisphere - to maximize passive solar gain. However, the use of solar gain, especially in temperate climate regions, is secondary to minimizing the overall house energy requirements. In climates and regions needing to reduce excessive summer passive solar heat gain, whether from direct or reflected sources, Brise soleil, trees, attached pergolas with vines, vertical gardens, green roofs, and other techniques are implemented.
Passive houses can be constructed from dense or lightweight materials, but some internal thermal mass is normally incorporated to reduce summer peak temperatures, maintain stable winter temperatures, and prevent possible overheating in spring or autumn before the higher sun angle "shades" mid-day wall exposure and window penetration. Exterior wall color, when the surface allows choice, for reflection or absorption insolation qualities depends on the predominant year-round ambient outdoor temperature. The use of deciduous trees and wall trellised or self attaching vines can assist in climates not at the temperature extremes.
Superinsulation
Passivhaus buildings employ superinsulation to significantly reduce the heat transfer through the walls, roof and floor compared to conventional buildings.[31] A wide range ofthermal insulation materials can be used to provide the required high R-values (low U-values, typically in the 0.10 to 0.15 W/(m².K) range). Special attention is given to eliminating thermal bridges.
A disadvantage resulting from the thickness of wall insulation required is that, unless the external dimensions of the building can be enlarged to compensate, the internal floor area of the building may be less compared to traditional construction.
In Sweden, to achieve passive house standards, the insulation thickness would be 335 mm (about 13 in) (0.10 W/(m².K)) and the roof 500 mm (about 20 in) (U-value 0.066 W/(m².K)).
Advanced window technology
Typical Passive House windows
To meet the requirements of the Passivhaus standard, windows are manufactured with exceptionally high R-values (low U-values, typically 0.85 to 0.70 W/(m².K) for the entire window including the frame). These normally combine triple-paneinsulated glazing (with a good solar heat-gain coefficient,[2][31] low-emissivity coatings, sealed argon or krypton gas filled inter-pane voids, and 'warm edge' insulating glass spacers) with air-seals and specially developed thermally broken window frames.
In Central Europe and most of the United States, for unobstructed south-facing Passivhaus windows, the heat gains from the sun are, on average, greater than the heat losses, even in mid-winter.
Airtightness
Building envelopes under the Passivhaus standard are required to be extremely airtight compared to conventional construction. This is achieved through air barriers, careful sealing of every construction joint in the building envelope, and sealing of all service penetrations.[31]
Airtightness minimizes the amount of warm — or cool — air that can pass through the structure, enabling the mechanical ventilation system to recover the heat before discharging the air externally.[
Ventilation
Use of passive natural ventilation is an integral component of passive house design where ambient temperature is conducive — either by singular or cross ventilation; by a simple opening or enhanced by the stack effect from smaller ingress with larger egress windows and/or clerestory-operable skylight.
When ambient climate is not conducive, mechanical heat recovery ventilation systems, with a heat recovery rate of over 80% and high-efficiency electronically commutated motors (ECM), are employed to maintain air quality, and to recover sufficient heat to dispense with a conventional central heating system.[2] Since passively designed buildings are essentially air-tight, the rate of air change can be optimized and carefully controlled at about 0.4 air changes per hour. All ventilation ducts are insulated and sealed against leakage.
Some Passivhaus builders promote the use of earth warming tubes (typically ≈200 mm (~7,9 in) diameter, ≈40 m (~130 ft) long at a depth of ≈1.5 m (~5 ft)). These are buried in the soil to act as earth-to-air heat exchangers and pre-heat (or pre-cool) the intake air for the ventilation system. In cold weather the warmed air also prevents ice formation in the heat recovery system's heat exchanger. Concerns about this technique have arisen in some climates due to problems with condensation and mold.[32]
Alternatively, an earth to air heat exchanger can use a liquid circuit instead of an air circuit, with a heat exchanger (battery) on the supply air.
Space heating
Passivhaus: In addition to the heat exchanger (centre), a micro-heat pump extracts heat from the exhaust air (left) and hot water heats the ventilation air (right). The ability to control building temperature using only the normal volume of ventilation air is fundamental.
In addition to using passive solar gain, Passivhaus buildings make extensive use of their intrinsic heat from internal sources—such as waste heat from lighting, white goods (major appliances) and other electrical devices (but not dedicated heaters)—as well as body heat from the people and other animals inside the building. This is due to the fact that people, on average, emit heat equivalent to 100 watts each of radiated thermal energy.
Together with the comprehensive energy conservation measures taken, this means that a conventional central heatingsystem is not necessary, although they are sometimes installed due to client skepticism.[33]
Instead, Passive houses sometimes have a dual purpose 800 to 1,500 watt heating and/or cooling element integrated with the supply air duct of the ventilation system, for use during the coldest days. It is fundamental to the design that all the heat required can be transported by the normal low air volume required for ventilation. A maximum air temperature of 50 °C (122 °F) is applied, to prevent any possible smell of scorching from dust that escapes the filters in the system.
The air-heating element can be heated by a small heat pump, by direct solar thermal energy, annualized geothermal solar, or simply by a natural gas or oil burner. In some cases a micro-heat pump is used to extract additional heat from the exhaust ventilation air, using it to heat either the incoming air or the hot water storage tank. Small wood-burning stoves can also be used to heat the water tank, although care is required to ensure that the room in which stove is located does not overheat.
Beyond the recovery of heat by the heat recovery ventilation unit, a well designed Passive house in the European climate should not need any supplemental heat source if the heating load is kept under 10W/m².[34]
Because the heating capacity and the heating energy required by a passive house both are very low, the particular energy source selected has fewer financial implications than in a traditional building, although renewable energy sources are well suited to such low loads.
Lighting and electrical appliances
See also: Daylighting, Passive daylighting, Active daylighting, and Ecological footprint
To minimize the total primary energy consumption, the many passive and active daylighting techniques are the first daytime solution to employ. For low light level days, non-daylighted spaces, and nighttime; the use of creative-sustainable lighting design using low-energy sources such as 'standard voltage' compact fluorescent lamps and solid-state lighting with Light-emitting diode-LED lamps, organic light-emitting diodes, and PLED - polymer light-emitting diodes; and 'low voltage' electrical filament-Incandescent light bulbs, and compact Metal halide, Xenon and Halogen lamps, can be used.
Solar powered exterior circulation, security, and landscape lighting - with photovoltaic cells on each fixture or connecting to a central Solar panel system, are available forgardens and outdoor needs. Low voltage systems can be used for more controlled or independent illumination, while still using less electricity than conventional fixtures and lamps. Timers, motion detection and natural light operation sensors reduce energy consumption, and light pollution even further for a Passivhaus setting.
Appliance consumer products meeting independent energy efficiency testing and receiving Ecolabel certification marks for reduced electrical-'natural-gas' consumption and product manufacturing carbon emission labels are preferred for use in Passive houses. The ecolabel certification marks of Energy Star and EKOenergy are examples.
Traits of passive houses
Typically, passive houses feature:
• Fresh, clean air: Note that for the parameters tested, and provided the filters (minimum F6) are maintained, HEPA quality air is provided. 0.3 air changes per hour (ACH) are recommended, otherwise the air can become "stale" (excess CO2, flushing of indoor air pollutants) and any greater, excessively dry (less than 40% humidity). This implies careful selection of interior finishes and furnishings, to minimize indoor air pollution from VOC's (e.g., formaldehyde). This can be counteracted somewhat by opening a window for a very brief time, by plants, and by indoor fountains.
• Because of the high resistance to heat flow (high R-value insulation), there are no "outside walls" which are colder than other walls.
• Homogeneous interior temperature: it is impossible to have single rooms (e.g. the sleeping rooms) at a different temperature from the rest of the house. Note that the relatively high temperature of the sleeping areas is physiologically not considered desirable by some building scientists. Bedroom windows can be cracked open slightly to alleviate this when necessary.
• Slow temperature changes: with ventilation and heating systems switched off, a passive house typically loses less than 0.5 °C (1 °F) per day (in winter), stabilizing at around 15 °C (59 °F) in the central European climate.
• Quick return to normal temperature: opening windows or doors for a short time has only a limited effect; after aperatures are closed, the air very quickly returns to the "normal" temperature.
ense with conventional heating systems. While this is an underlying
objective of the Passivhaus standard, some type of heating will still be
required and most Passivhaus buildings do include a system to provide
supplemental space heating. This is normally distributed through the
low-volume heat recovery
ventilation system that is
required to maintain air quality, rather than by a conventional hydronic or
high-volume forced-air heating system, as described in the space heating section below.
Construction costs
In Passivhaus buildings, the cost savings from dispensing with the
conventional heating system can be used to fund the upgrade of the building
envelope and the heat recovery ventilation system. With careful design and
increasing competition in the supply of the specifically designed Passivhaus
building products, in Germany it is now possible to construct buildings for the
same cost as those built to normal German building standards, as was done with the Passivhaus apartments at Vauban, Freiburg.[25]On average, however, passive houses are still up to 14% more
expensive upfront than conventional buildings.[26]
Evaluations have indicated that while it is technically possible,
the costs of meeting the Passivhaus standard increase significantly when
building in Northern Europe above 60° latitude.[27][28] European cities at approximately 60° include Helsinki in
Finland and Bergen in Norway. London is at 51°; Moscow is at 55°.
These facts have led a number of architects to construct buildings
that use the ground under the building for massive heat storage to shift heat
production from the winter to the summer. Some buildings can also shift cooling
from the summer to the winter. At least one designer uses a passive
thermosiphon carrying only air, so the process can be accomplished without
expensive, unreliable machinery.[29] (See also Annualized geo solar)
Design and construction
The Passivhaus uses a combination oflow-energy
building techniques and
technologies.
Achieving the major decrease in heating energy consumption
required by the standard involves a shift in approach to building design and
construction. Design may be assisted by use of the 'Passivhaus Planning
Package' (PHPP),[30] which
uses specifically designed computer simulations.
To achieve the standards, a number of techniques and technologies
are used in combination:[2]
Passive solar design and landscape
Passive solar building
design and energy-efficient
landscaping support the
Passive house energy conservation and can integrate them into a neighborhood and environment. Following passive
solar building techniques, where
possible buildings are compact in shape to reduce their surface area, with
principal windows oriented towards the equator - south in the northern
hemisphere and north in the southern hemisphere - to maximize passive solar gain. However, the use of solar gain, especially in temperate climate regions, is secondary to minimizing the
overall house energy requirements. In climates and regions needing to reduce
excessive summer passive solar heat gain, whether from direct or reflected
sources, Brise soleil, trees, attached pergolas with vines, vertical gardens, green roofs, and other techniques are implemented.
Passive houses can be constructed from dense or lightweight
materials, but some internal thermal mass is normally incorporated to reduce summer peak temperatures,
maintain stable winter temperatures, and prevent possible overheating in spring
or autumn before the higher sun
angle "shades"
mid-day wall exposure and window penetration. Exterior wall color, when the
surface allows choice, for reflection or absorption insolation qualities depends on the predominant year-round ambient
outdoor temperature. The use of deciduous trees and wall trellised or self attaching vines can assist in
climates not at the temperature extremes.
Superinsulation
Passivhaus buildings employ superinsulation to significantly reduce the heat transfer through the walls,
roof and floor compared to conventional buildings.[31] A wide range ofthermal insulation materials can be used to provide the
required high R-values (low U-values,
typically in the 0.10 to 0.15 W/(m².K) range). Special attention is given to
eliminating thermal bridges.
A disadvantage resulting from the thickness of wall insulation
required is that, unless the external dimensions of the building can be
enlarged to compensate, the internal floor area of the building may be less
compared to traditional construction.
In Sweden, to achieve passive house standards, the insulation
thickness would be 335 mm (about 13 in) (0.10 W/(m².K)) and the roof
500 mm (about 20 in) (U-value 0.066 W/(m².K)).
Advanced window technology
Typical Passive House windows
To meet the requirements of the Passivhaus standard, windows are
manufactured with exceptionally high R-values (low U-values, typically 0.85 to 0.70
W/(m².K) for the entire window including the frame). These normally combine
triple-paneinsulated glazing (with a good solar heat-gain coefficient,[2][31] low-emissivity coatings, sealed argon or krypton gas
filled inter-pane voids, and 'warm edge' insulating glass spacers) with
air-seals and specially developed thermally broken window frames.
In Central Europe and most of the United States, for unobstructed south-facing Passivhaus windows, the heat gains
from the sun are, on average, greater than the heat losses, even in mid-winter.
Airtightness
Building envelopes under the Passivhaus standard are required to
be extremely airtight compared to conventional construction.
This is achieved through air barriers, careful sealing of every construction
joint in the building envelope, and sealing of all service penetrations.[31]
Airtightness minimizes the amount of warm — or cool — air that can
pass through the structure, enabling the mechanical ventilation system to
recover the heat before discharging the air externally.[2]
Ventilation
Use of passive natural ventilation is an integral component of passive house
design where ambient temperature is conducive — either by singular or cross
ventilation; by a simple opening or enhanced by the stack effect from smaller ingress with larger egress windows and/or clerestory-operable skylight.
When ambient climate is not conducive, mechanical heat recovery
ventilation systems, with a
heat recovery rate of over 80% and high-efficiency electronically
commutated motors (ECM), are
employed to maintain air quality, and to recover sufficient heat to dispense
with a conventional central heating system.[2] Since passively designed buildings are essentially air-tight, the rate of air change can be optimized and carefully controlled
at about 0.4 air changes per hour. All ventilation ducts are insulated and sealed
against leakage.
Some Passivhaus builders promote the use of earth warming
tubes (typically
≈200 mm (~7,9 in) diameter, ≈40 m (~130 ft) long at a depth of ≈1.5 m
(~5 ft)). These are buried in the soil to act as earth-to-air heat
exchangers and pre-heat (or pre-cool) the intake air for the ventilation
system. In cold weather the warmed air also prevents ice formation in the heat recovery
system's heat exchanger. Concerns about this technique have arisen in
some climates due to problems with condensation and mold.[32]
Alternatively, an earth to air heat exchanger can use a liquid
circuit instead of an air circuit, with a heat exchanger (battery) on the
supply air.
Space heating
Passivhaus:
In addition to the heat exchanger (centre), a micro-heat pump extracts heat
from the exhaust air (left) and hot water heats the ventilation air (right).
The ability to control building temperature using only the normal volume of
ventilation air is fundamental.
In addition to using passive solar gain, Passivhaus buildings make extensive use of their intrinsic heat
from internal sources—such as waste heat from lighting, white goods (major appliances) and other electrical devices (but not
dedicated heaters)—as well as body heat from the people and other animals
inside the building. This is due to the fact that people, on average, emit heat
equivalent to 100 watts each of radiated thermal energy.
Together with the comprehensive energy conservation measures taken, this means that a
conventional central heatingsystem is not necessary, although they are
sometimes installed due to client skepticism.[33]
Instead, Passive houses sometimes have a dual purpose 800 to 1,500 watt heating and/or cooling element integrated
with the supply air duct of the ventilation system, for use during the coldest
days. It is fundamental to the design that all the heat required can be
transported by the normal low air volume required for ventilation. A maximum
air temperature of 50 °C (122 °F) is applied, to prevent any possible smell of
scorching from dust that escapes the filters in the system.
The air-heating element can be heated by a small heat pump, by direct solar thermal energy, annualized
geothermal solar, or simply by a natural gas or oil burner. In some cases a micro-heat pump is used to extract additional
heat from the exhaust ventilation air, using it to heat either the incoming air
or the hot water storage tank. Small wood-burning stoves can also be used to
heat the water tank, although care is required to ensure that the room in which
stove is located does not overheat.
Beyond the recovery of heat by the heat recovery ventilation unit,
a well designed Passive house in the European climate should not need any
supplemental heat source if the heating load is kept under 10W/m².[34]
Because the heating capacity and the heating energy required by a
passive house both are very low, the particular energy source selected has fewer financial implications
than in a traditional building, although renewable energy sources are well suited to such low loads.
Lighting and electrical appliances
See also: Daylighting, Passive daylighting, Active daylighting, and Ecological footprint
To minimize the total primary energy consumption, the many passive and active daylighting techniques
are the first daytime solution to employ. For low light level days,
non-daylighted spaces, and nighttime; the use of creative-sustainable lighting design using low-energy sources such as 'standard voltage' compact
fluorescent lamps and solid-state lighting with Light-emitting diode-LED lamps, organic
light-emitting diodes, and PLED - polymer light-emitting diodes; and 'low voltage' electrical filament-Incandescent light bulbs, and compact
Metal halide, Xenon and Halogen lamps, can be used.
Solar powered exterior circulation, security, and landscape lighting - with photovoltaic cells on each fixture or connecting to a central Solar panel system, are available forgardens and outdoor needs. Low voltage systems can
be used for more controlled or independent illumination, while still using less
electricity than conventional fixtures and lamps. Timers, motion detection and natural light operation sensors reduce energy consumption, and light pollution even further for a Passivhaus setting.
Appliance consumer products meeting independent energy efficiency testing and
receiving Ecolabel certification marks for reduced electrical-'natural-gas'
consumption and product manufacturing carbon emission labels are preferred for use in Passive houses.
The ecolabel certification marks of Energy Star and EKOenergy are examples.
Traits of passive houses
Typically, passive houses feature:
- Fresh, clean air: Note that for
the parameters tested, and provided the filters (minimum F6) are
maintained, HEPA quality
air is provided. 0.3 air changes per hour (ACH) are recommended, otherwise
the air can become "stale" (excess CO2, flushing of
indoor air pollutants) and any greater, excessively dry (less than 40%
humidity). This implies careful selection of interior finishes and
furnishings, to minimize indoor air pollution from VOC's (e.g., formaldehyde).
This can be counteracted somewhat by opening a window for a very brief
time, by plants, and by indoor fountains.
- Because of the high resistance
to heat flow (high R-value insulation), there are no "outside
walls" which are colder than other walls.
- Homogeneous interior
temperature: it is impossible to have single rooms (e.g. the sleeping
rooms) at a different temperature from the rest of the house. Note that
the relatively high temperature of the sleeping areas is physiologically
not considered desirable by some building scientists. Bedroom windows can
be cracked open slightly to alleviate this when necessary.
- Slow temperature changes: with
ventilation and heating systems switched off, a passive house typically
loses less than 0.5 °C (1 °F) per day (in winter), stabilizing at around
15 °C (59 °F) in the central European climate.
- Quick return to normal
temperature: opening windows or doors for a short time has only a limited
effect; after aperatures are closed, the air very quickly returns to the
"normal" temperature.
, others, such as superinsulation, already existed, and the
concept of passive solar building design dates back to antiquity.
[edit]Standards
The Passivhaus standard for central Europe requires that the
building fulfills the following requirements:[22][23]
The building must be designed to have an annual heating demand as
calculated with the Passivhaus Planning Package of not more than 15 kWh/m² per
year (4746 btu/ft² per year) in heating and 15 kWh/m² per year cooling energy
OR to be designed with a peak heat load of 10W/m²
Total primary energy (source energy for electricity and etc.)
consumption (primary energy for heating, hot water and electricity) must not be
more than 120 kWh/m² per year (3.79 × 104 btu/ft² per year)
The building must not leak more air than 0.6 times the house
volume per hour (n50 ≤ 0.6 / hour) at 50 Pa (N/m²) as tested by a blower door
Recommendations
Further, the specific heat load for the heating source at design
temperature is recommended, but not required, to be less than 10 W/m² (3.17
btu/h.ft² per hour).
These standards are much higher than houses built to most normal
building codes. For comparisons, see the international comparisons section
below.
National partners within the 'consortium for the Promotion of
European Passive Houses' are thought to have some flexibility to adapt these
limits locally.[24]
Space heating requirement
By achieving the Passivhaus standards, qualified buildings are
able to dispense with conventional heating systems. While this is an underlying
objective of the Passivhaus standard, some type of heating will still be
required and most Passivhaus buildings do include a system to provide
supplemental space heating. This is normally distributed through the low-volume
heat recovery ventilation system that is required to maintain air quality,
rather than by a conventional hydronic or high-volume forced-air heating
system, as described in the space heating section below.
Construction costs
In Passivhaus buildings, the cost savings from dispensing with the
conventional heating system can be used to fund the upgrade of the building
envelope and the heat recovery ventilation system. With careful design and
increasing competition in the supply of the specifically designed Passivhaus
building products, in Germany it is now possible to construct buildings for the
same cost as those built to normal German building standards, as was done with
the Passivhaus apartments at Vauban, Freiburg.[25] On average, however, passive
houses are still up to 14% more expensive upfront than conventional
buildings.[26]
Evaluations have indicated that while it is technically possible,
the costs of meeting the Passivhaus standard increase significantly when
building in Northern Europe above 60° latitude.[27][28] European cities at
approximately 60° include Helsinki in Finland and Bergen in Norway. London is
at 51°; Moscow is at 55°.
These facts have led a number of architects to construct buildings
that use the ground under the building for massive heat storage to shift heat
production from the winter to the summer. Some buildings can also shift cooling
from the summer to the winter. At least one designer uses a passive
thermosiphon carrying only air, so the process can be accomplished without
expensive, unreliable machinery.[29] (See also Annualized geo solar)
Design and construction
The Passivhaus uses a combination of low-energy building
techniques and technologies.
Achieving the major decrease in heating energy consumption
required by the standard involves a shift in approach to building design and
construction. Design may be assisted by use of the 'Passivhaus Planning
Package' (PHPP),[30] which uses specifically designed computer simulations.
To achieve the standards, a number of techniques and technologies
are used in combination:[2]
Passive solar design and landscape
Passive solar building design and energy-efficient landscaping
support the Passive house energy conservation and can integrate them into a
neighborhood and environment. Following passive solar building techniques,
where possible buildings are compact in shape to reduce their surface area,
with principal windows oriented towards the equator - south in the northern
hemisphere and north in the southern hemisphere - to maximize passive solar
gain. However, the use of solar gain, especially in temperate climate regions,
is secondary to minimizing the overall house energy requirements. In climates
and regions needing to reduce excessive summer passive solar heat gain, whether
from direct or reflected sources, trees, attached pergolas with vines, vertical
gardens, green roofs, and other techniques are implemented.
Passive houses can be constructed from dense or lightweight
materials, but some internal thermal mass is normally incorporated to reduce
summer peak temperatures, maintain stable winter temperatures, and prevent
possible overheating in spring or autumn before the higher sun angle
"shades" mid-day wall exposure and window penetration. Exterior wall
color, when the surface allows choice, for reflection or absorption insolation
qualities depends on the predominant year-round ambient outdoor temperature.
The use of deciduous trees and wall trellised or self attaching vines can
assist in climates not at the temperature extremes.
Superinsulation
Passivhaus buildings employ superinsulation to significantly
reduce the heat transfer through the walls, roof and floor compared to
conventional buildings.[31] A wide range of thermal insulation materials can be
used to provide the required high R-values (low U-values, typically in the 0.10
to 0.15 W/(m².K) range). Special attention is given to eliminating thermal
bridges.
A disadvantage resulting from the thickness of wall insulation
required is that, unless the external dimensions of the building can be
enlarged to compensate, the internal floor area of the building may be less
compared to traditional construction.
In Sweden, to achieve passive house standards, the insulation
thickness would be 335 mm (about 13 in) (0.10 W/(m².K)) and the roof 500 mm
(about 20 in) (U-value 0.066 W/(m².K)).
Advanced window technology
Typical Passive House windows
To meet the requirements of the Passivhaus standard, windows are
manufactured with exceptionally high R-values (low U-values, typically 0.85 to
0.70 W/(m².K) for the entire window including the frame). These normally
combine triple-pane insulated glazing (with a good solar heat-gain
coefficient,[2][31] low-emissivity coatings, sealed argon or krypton gas filled
inter-pane voids, and 'warm edge' insulating glass spacers) with air-seals and
specially developed thermally broken window frames.
In Central Europe and most of the United States, for unobstructed
south-facing Passivhaus windows, the heat gains from the sun are, on average,
greater than the heat losses, even in mid-winter.
Airtightness
Building envelopes under the Passivhaus standard are required to
be extremely airtight compared to conventional construction. This is achieved
through air barriers, careful sealing of every construction joint in the
building envelope, and sealing of all service penetrations.[31]
Airtightness minimizes the amount of warm — or cool — air that can
pass through the structure, enabling the mechanical ventilation system to
recover the heat before discharging the air externally.[2]
[edit]Ventilation
Use of passive natural ventilation is an integral component of
passive house design where ambient temperature is conducive — either by
singular or cross ventilation; by a simple opening or enhanced by the stack
effect from smaller ingress with larger egress windows and/or
clerestory-operable skylight.
When ambient climate is not conducive, mechanical heat recovery
ventilation systems, with a heat recovery rate of over 80% and high-efficiency
electronically commutated motors (ECM), are employed to maintain air quality,
and to recover sufficient heat to dispense with a conventional central heating
system.[2] Since passively designed buildings are essentially air-tight, the
rate of air change can be optimized and carefully controlled at about 0.4 air
changes per hour. All ventilation ducts are insulated and sealed against
leakage.
Some Passivhaus builders promote the use of earth warming tubes
(typically ≈200 mm (~7,9 in) diameter, ≈40 m (~130 ft) long at a depth of ≈1.5
m (~5 ft)). These are buried in the soil to act as earth-to-air heat exchangers
and pre-heat (or pre-cool) the intake air for the ventilation system. In cold
weather the warmed air also prevents ice formation in the heat recovery
system's heat exchanger. Concerns about this technique have arisen in some
climates due to problems with condensation and mold.[32]
Alternatively, an earth to air heat exchanger can use a liquid
circuit instead of an air circuit, with a heat exchanger (battery) on the
supply air.
Space heating
Passivhaus: In addition to the heat exchanger (centre), a micro-heat
pump extracts heat from the exhaust air (left) and hot water heats the
ventilation air (right). The ability to control building temperature using only
the normal volume of ventilation air is fundamental.
In addition to using passive solar gain, Passivhaus buildings make
extensive use of their intrinsic heat from internal sources—such as waste heat
from lighting, white goods (major appliances) and other electrical devices (but
not dedicated heaters)—as well as body heat from the people and other animals
inside the building. This is due to the fact that people, on average, emit heat
equivalent to 100 watts each of radiated thermal energy.
Together with the comprehensive energy conservation measures
taken, this means that a conventional central heating system is not necessary,
although they are sometimes installed due to client skepticism.[33]
Instead, Passive houses sometimes have a dual purpose 800 to 1,500
watt heating and/or cooling element integrated with the supply air duct of the
ventilation system, for use during the coldest days. It is fundamental to the
design that all the heat required can be transported by the normal low air
volume required for ventilation. A maximum air temperature of 50 °C (122 °F) is
applied, to prevent any possible smell of scorching from dust that escapes the
filters in the system.
The air-heating element can be heated by a small heat pump, by
direct solar thermal energy, annualized geothermal solar, or simply by a
natural gas or oil burner. In some cases a micro-heat pump is used to extract
additional heat from the exhaust ventilation air, using it to heat either the
incoming air or the hot water storage tank. Small wood-burning stoves can also
be used to heat the water tank, although care is required to ensure that the room
in which stove is located does not overheat.
Beyond the recovery of heat by the heat recovery ventilation unit,
a well designed Passive house in the European climate should not need any
supplemental heat source if the heating load is kept under 10W/m².[34]
Because the heating capacity and the heating energy required by a
passive house both are very low, the particular energy source selected has
fewer financial implications than in a traditional building, although renewable
energy sources are well suited to such low loads.
[edit]Lighting and electrical appliances
See also: Daylighting, Passive daylighting, Active daylighting,
and Ecological footprint
To minimize the total primary energy consumption, the many passive
and active daylighting techniques are the first daytime solution to employ. For
low light level days, non-daylighted spaces, and nighttime; the use of
creative-sustainable lighting design using low-energy sources such as 'standard
voltage' compact fluorescent lamps and solid-state lighting with Light-emitting
diode-LED lamps, organic light-emitting diodes, and PLED - polymer
light-emitting diodes; and 'low voltage' electrical filament-Incandescent light
bulbs, and compact Metal halide, Xenon and Halogen lamps, can be used.
Solar powered exterior circulation, security, and landscape
lighting - with photovoltaic cells on each fixture or connecting to a central
Solar panel system, are available for gardens and outdoor needs. Low voltage
systems can be used for more controlled or independent illumination, while
still using less electricity than conventional fixtures and lamps. Timers,
motion detection and natural light operation sensors reduce energy consumption,
and light pollution even further for a Passivhaus setting.
Appliance consumer products meeting independent energy efficiency
testing and receiving Ecolabel certification marks for reduced
electrical-'natural-gas' consumption and product manufacturing carbon emission
labels are preferred for use in Passive houses. The ecolabel certification
marks of Energy Star and EKOenergy are examples.
Traits of passive houses
Typically, passive houses feature:
Fresh, clean air: Note that for the parameters tested, and
provided the filters (minimum F6) are maintained, HEPA quality air is provided.
0.3 air changes per hour (ACH) are recommended, otherwise the air can become
"stale" (excess CO2, flushing of indoor air pollutants) and any
greater, excessively dry (less than 40% humidity). This implies careful
selection of interior finishes and furnishings, to minimize indoor air
pollution from VOC's (e.g., formaldehyde). This can be counteracted somewhat by
opening a window for a very brief time, by plants, and by indoor fountains.
Because of the high resistance to heat flow (high R-value
insulation), there are no "outside walls" which are colder than other
walls.
Homogeneous interior temperature: it is impossible to have single
rooms (e.g. the sleeping rooms) at a different temperature from the rest of the
house. Note that the relatively high temperature of the sleeping areas is
physiologically not considered desirable by some building scientists. Bedroom
windows can be cracked open slightly to alleviate this when necessary.
Slow temperature changes: with ventilation and heating systems
switched off, a passive house typically loses less than 0.5 °C (1 °F) per day
(in winter), stabilizing at around 15 °C (59 °F) in the central European
climate.
Quick return to normal temperature: opening windows or doors for a
short time has only a limited effect; after aperatures are closed, the air very
quickly returns to the "normal" temperature.
Standards
The Passivhaus standard for central Europe requires that the
building fulfills the following requirements:[22][23]
·
The building must be
designed to have an annual heating demand as calculated with the Passivhaus
Planning Package of not more than 15 kWh/m² per year (4746 btu/ft² per year) in heating
and 15 kWh/m² per year cooling energy OR to be designed
with a peak heat load of 10W/m²
·
Total primary energy (source energy for electricity and etc.)
consumption (primary energy for heating, hot water andelectricity) must not be more than 120 kWh/m² per year (3.79 × 104 btu/ft²
per year)
·
The building must not
leak more air than 0.6 times the house volume per hour (n50 ≤
0.6 / hour) at 50 Pa (N/m²) as tested by a blower door
Recommendations
·
Further, the specific
heat load for the heating source at design temperature is recommended, but not
required, to be less than 10 W/m² (3.17 btu/h.ft²
per hour).
These standards are much higher than houses built to most normal
building codes. For comparisons, see the international
comparisons section below.
National partners within the 'consortium for the Promotion of
European Passive Houses' are thought to have some flexibility to adapt these
limits locally
Space heating requirement
By achieving the Passivhaus standards, qualified buildings are
able to dispense with conventional heating systems. While this is an underlying
objective of the Passivhaus standard, some type of heating will still be
required and most Passivhaus buildings do include a system to provide
supplemental space heating. This is normally distributed through the
low-volume heat
recovery ventilation system that is
required to maintain air quality, rather than by a conventional hydronic or
high-volume forced-air heating system, as described in the space heating section below.
Construction costs
In Passivhaus buildings, the cost savings from dispensing with the
conventional heating system can be used to fund the upgrade of the building
envelope and the heat recovery ventilation system. With careful design and
increasing competition in the supply of the specifically designed Passivhaus
building products, in Germany it is now possible to construct buildings for the
same cost as those built to normal German building standards, as was done with the Passivhaus apartments
at Vauban, Freiburg.[25]On average, however, passive houses are still up to 14% more
expensive upfront than conventional buildings.[26]
Evaluations have indicated that while it is technically possible,
the costs of meeting the Passivhaus standard increase significantly when
building in Northern Europe above 60° latitude.[27][28] European cities at approximately 60° include Helsinki in
Finland and Bergen in Norway. London is at 51°; Moscow is at 55°.
These facts have led a number of architects to construct buildings
that use the ground under the building for massive heat storage to shift heat
production from the winter to the summer. Some buildings can also shift cooling
from the summer to the winter. At least one designer uses a passive
thermosiphon carrying only air, so the process can be accomplished without
expensive, unreliable machinery.[29] (See also Annualized geo solar
Design and construction
The Passivhaus uses a combination oflow-energy building techniques and technologies.
Achieving the major decrease in heating energy consumption
required by the standard involves a shift in approach to building design and
construction. Design may be assisted by use of the 'Passivhaus Planning
Package' (PHPP),[30] which uses specifically
designed computer simulations.
To achieve the standards, a number of techniques and technologies
are used in combination
[Passive solar design and landscape
Passive
solar building design and energy-efficient
landscaping support the
Passive house energy conservation and can integrate them into a neighborhood and environment. Following passive solar building techniques, where possible buildings are compact in shape
to reduce their surface area, with principal windows oriented towards the
equator - south in the northern hemisphere and north in the southern hemisphere
- to maximize passive solar gain. However, the use of solar gain, especially in temperate climate regions, is secondary to minimizing the
overall house energy requirements. In climates and regions needing to reduce
excessive summer passive solar heat gain, whether from direct or reflected
sources, Brise soleil, trees, attached pergolas with vines, vertical gardens, green roofs, and other techniques are implemented.
Passive houses can be constructed from dense or lightweight
materials, but some internal thermal mass is normally incorporated to reduce summer peak temperatures,
maintain stable winter temperatures, and prevent possible overheating in spring
or autumn before the higher sun angle "shades"
mid-day wall exposure and window penetration. Exterior wall color, when the
surface allows choice, for reflection or absorption insolation qualities depends on the predominant year-round ambient
outdoor temperature. The use of deciduous trees and wall trellised or self attaching vines can assist in
climates not at the temperature extremes.
Superinsulation
Passivhaus buildings employ superinsulation to significantly reduce the heat transfer
through the walls, roof and floor compared to conventional buildings.[31] A wide range ofthermal insulation materials can be used to provide the
required high R-values (low U-values, typically in the 0.10 to 0.15 W/(m².K) range). Special attention
is given to eliminating thermal bridges.
A disadvantage resulting from the thickness of wall insulation
required is that, unless the external dimensions of the building can be
enlarged to compensate, the internal floor area of the building may be less
compared to traditional construction.
In Sweden, to achieve passive house standards, the insulation
thickness would be 335 mm (about 13 in) (0.10 W/(m².K)) and the roof
500 mm (about 20 in) (U-value 0.066 W/(m².K)).
Advanced window technology
Typical Passive House windows
To meet the requirements of the Passivhaus standard, windows are
manufactured with exceptionally high R-values (low U-values, typically 0.85 to 0.70
W/(m².K) for the entire window including the frame). These normally combine
triple-paneinsulated glazing (with a good solar heat-gain coefficient,[2][31] low-emissivity coatings, sealed argon or krypton gas filled inter-pane voids, and 'warm edge' insulating
glass spacers) with air-seals and specially developed thermally broken window
frames.
In Central Europe and most of the United States, for unobstructed south-facing Passivhaus
windows, the heat gains from the sun are, on average, greater than the heat
losses, even in mid-winter.
Airtightness
Building envelopes under the Passivhaus standard are required to
be extremely airtight compared to conventional construction.
This is achieved through air barriers, careful sealing of every construction
joint in the building envelope, and sealing of all service penetrations.[31]
Airtightness minimizes the amount of warm — or cool — air that can
pass through the structure, enabling the mechanical ventilation system to
recover the heat before discharging the air externally.[
Ventilation
Use of passive natural ventilation is an integral component of passive house
design where ambient temperature is conducive — either by singular or cross
ventilation; by a simple opening or enhanced by the stack effect from smaller ingress with larger egress windows and/or clerestory-operable skylight.
When ambient climate is not conducive, mechanical heat
recovery ventilation systems, with a
heat recovery rate of over 80% and high-efficiency electronically commutated motors (ECM), are employed to maintain air
quality, and to recover sufficient heat to dispense with a conventional central
heating system.[2] Since passively designed buildings are essentially air-tight, the rate of air change can be optimized and carefully controlled
at about 0.4 air changes per hour. All ventilation ducts are insulated and sealed
against leakage.
Some Passivhaus builders promote the use of earth
warming tubes (typically
≈200 mm (~7,9 in) diameter, ≈40 m (~130 ft) long at a depth of ≈1.5 m
(~5 ft)). These are buried in the soil to act as earth-to-air heat
exchangers and pre-heat (or pre-cool) the intake air for the ventilation
system. In cold weather the warmed air also prevents ice formation in the
heat recovery system's heat exchanger. Concerns about this technique have arisen in
some climates due to problems with condensation and mold.[32]
Alternatively, an earth to air heat exchanger can use a liquid
circuit instead of an air circuit, with a heat exchanger (battery) on the
supply air.
Space heating
Passivhaus: In addition to the
heat exchanger (centre), a micro-heat pump extracts heat from the exhaust air
(left) and hot water heats the ventilation air (right). The ability to control
building temperature using only the normal volume of ventilation air is
fundamental.
In addition to using passive solar gain, Passivhaus buildings make extensive use of their intrinsic heat
from internal sources—such as waste heat from lighting, white goods (major appliances) and other electrical devices (but not
dedicated heaters)—as well as body heat from the people and other animals
inside the building. This is due to the fact that people, on average, emit heat
equivalent to 100 watts each of radiated thermal
energy.
Together with the comprehensive energy conservation measures taken, this means that a
conventional central heatingsystem is not necessary, although they are
sometimes installed due to client skepticism.[33]
Instead, Passive houses sometimes have a dual purpose 800 to
1,500 watt heating and/or cooling element integrated with the supply
air duct of the ventilation system, for use during the coldest days. It is
fundamental to the design that all the heat required can be transported by the
normal low air volume required for ventilation. A maximum air temperature of 50
°C (122 °F) is applied, to prevent any possible smell of scorching from dust
that escapes the filters in the system.
The air-heating element can be heated by a small heat pump, by direct solar thermal energy, annualized
geothermal solar, or simply by a natural gas or oil burner. In some cases a micro-heat pump is used to extract additional
heat from the exhaust ventilation air, using it to heat either the incoming air
or the hot water storage tank. Small wood-burning stoves can also be used to
heat the water tank, although care is required to ensure that the room in which
stove is located does not overheat.
Beyond the recovery of heat by the heat recovery ventilation unit,
a well designed Passive house in the European climate should not need any
supplemental heat source if the heating load is kept under 10W/m².[34]
Because the heating capacity and the heating energy required by a
passive house both are very low, the particular energy
source selected has fewer
financial implications than in a traditional building, although renewable energy sources are well suited to such low loads.
Lighting and electrical appliances
See also: Daylighting, Passive daylighting, Active daylighting, and Ecological footprint
To minimize the total primary energy consumption, the many passive and active daylighting techniques are the first
daytime solution to employ. For low light level days, non-daylighted spaces,
and nighttime; the use of creative-sustainable lighting design using low-energy sources such as 'standard
voltage' compact
fluorescent lamps and solid-state lighting with Light-emitting diode-LED lamps, organic
light-emitting diodes, and PLED - polymer
light-emitting diodes; and 'low
voltage' electrical filament-Incandescent light
bulbs, and compact Metal halide, Xenon and Halogen lamps, can be used.
Solar powered exterior circulation, security, and landscape lighting - with photovoltaic cells on each fixture or connecting to a
central Solar panel system, are available forgardens and
outdoor needs. Low voltage systems can be used for more controlled or
independent illumination, while still using less electricity than conventional
fixtures and lamps. Timers, motion detection and natural light operation sensors reduce energy
consumption, and light pollution even further for a Passivhaus setting.
Appliance consumer products meeting independent energy efficiency
testing and receiving Ecolabel certification marks for reduced electrical-'natural-gas'
consumption and product manufacturing carbon emission labels are preferred for use in Passive houses.
The ecolabel certification marks of Energy Star and EKOenergy are
examples.
Typically, passive houses feature:
·
Fresh, clean air: Note
that for the parameters tested, and provided the filters (minimum F6) are
maintained, HEPA quality air is provided. 0.3 air changes per hour (ACH) are
recommended, otherwise the air can become "stale" (excess CO2,
flushing of indoor air pollutants) and any greater, excessively dry (less than
40% humidity). This implies careful selection of interior finishes and
furnishings, to minimize indoor air pollution from VOC's (e.g., formaldehyde). This can be counteracted somewhat by opening a window for a
very brief time, by plants, and by indoor fountains.
·
Because of the high
resistance to heat flow (high R-value insulation), there are no "outside
walls" which are colder than other walls.
·
Homogeneous interior
temperature: it is impossible to have single rooms (e.g. the sleeping rooms) at
a different temperature from the rest of the house. Note that the relatively
high temperature of the sleeping areas is physiologically not considered
desirable by some building scientists. Bedroom windows can be cracked open
slightly to alleviate this when necessary.
·
Slow temperature
changes: with ventilation and heating systems switched off, a passive house
typically loses less than 0.5 °C (1 °F) per day (in winter), stabilizing at
around 15 °C (59 °F) in the central European climate.
·
Quick return to normal
temperature: opening windows or doors for a short time has only a limited effect; after aperatures are
closed, the air very quickly returns to the "normal" temperature.
Subscribe to: